Fault Trend Detection Using Three-Dimension Survey A Case Study in Central Iran

Publish Year: 1390
نوع سند: مقاله کنفرانسی
زبان: English
View: 1,137

This Paper With 5 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

SMEC08_027

تاریخ نمایه سازی: 4 اسفند 1391

Abstract:

Resistivity electrical changes in vertical, horizontal and in the direction that is perpendicular to the survey line, is measured in 3D surveys. 3D electric data illustrate a 3D image from subsurface layers, therefore combination of 3D electric results and surface geology is appreciated as helpful technique in electric datainterpretation. What is carried out for performing a 3D survey is as follows: first a 2D survey is carried out in the survey field and then collected data are interpretated.When the subsurface layers are defined clearly, an area is selected and a suitable grid for 3D survey is designed. After data acquisition, by using a 3D interpretation software, data points are interpretated. Finally, the results are compared with theresult of 2D configuration. In this study, the main objective is the detection of a fault trend by using pole–pole electrode array which is commonly used for 3D surveys.This survey method by using a 3D interpretation model gives accurate results of subsurface structures. In order to confirm the abilities of this method for faultdetection, after checking the final results of 2D Shlumberger array on a fault trend in Anarak area in Esfehan province, an square grid with a 60 meters long, was designed and data acquisition was carried out. Then potentional values (476 datapoints) were inserted into a provided program in MATLAB software for calculation the apparent resistivity. After data interpretation by using RES3DINV software, the fault trend was detected in vertical and horizontal sections. The results show considerable ability of 3D surveys for fault detection

Keywords:

Geo electrical 3D surveys , Pole-Pole array , Fault trend detection

Authors

Mojgan Ostovari

Islamic Azad University,Sceince And Research Branch,

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Loke, M.H., 1999, Electrical imaging surveys for environmenta and engineering ...
  • Bevan , Bruce W., 2000, The pole-pole Resistivity Array Compared ...
  • Garman.K. Michael. Purcel. Scott F.293. Three-D imensional Electrical Resistivity Surveys ...
  • Denchik. N. L.Marescot _ 2005, Choice of effective electrode array ...
  • نمایش کامل مراجع