CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Effect of Fixed versus Removable Appliances for Mandibular Advancement on Pharyngeal Airway of Growing Individuals

عنوان مقاله: Effect of Fixed versus Removable Appliances for Mandibular Advancement on Pharyngeal Airway of Growing Individuals
شناسه ملی مقاله: JR_ORTHO-18-2_002
منتشر شده در در سال 1402
مشخصات نویسندگان مقاله:

Faheem Arif - Department of Orthodontics, Coorg Institute of Dental Sciences, Virajpet, Karnataka, India
Goutham Reddy - Department of Orthodontics, Coorg Institute of Dental Sciences, Virajpet, Karnataka, India
Sanju Somaiah - Department of Orthodontics, Coorg Institute of Dental Sciences, Virajpet, Karnataka, India
Sunil Muddaiah - Department of Orthodontics, Coorg Institute of Dental Sciences, Virajpet, Karnataka, India

خلاصه مقاله:
Aim: Dental malocclusion and jaw misalignments are the foremost reasons for airway constriction. To facilitate anterior mandibular repositioning and the concomitant anterior positioning of the tongue can induce the expansion of the pharyngeal airway. The study aimed to compare comprehensive treatment outcomes of fixed and removable mandibular advancement appliances on the width of the pharyngeal airway space. Methods: Twenty growing patients with skeletal Class II malocclusion were placed into two groups: Advansync۲ and twin block. Patients were advised to use mandibular advancement appliances (MAA) for ۹–۱۲ months. Lateral cephalograms and the Epworth Sleepiness Scale (ESS) were evaluated to assess alterations in the pharyngeal airway space and quality of sleep at two intervals. The chi-square test, one-way ANOVA and Duncan’s post hoc test were used for statistical analysis. P-values<۰.۰۵ were considered as significant. Results: Based on the results, only the change in PNS-V measurements indicated a significant difference between appliances. Advansync۲ showed more change (۰.۷۰±۲.۴۵ mm) compared to twin block (-۱.۸۰±۲.۳۴ mm), indicating a statistically significant difference (p=۰.۰۳۲). Conclusion: A significant reduction in the ESS score in both groups was observed without any significant differences between them.

کلمات کلیدی:
Keywords: Advansync۲, Twin block, Epworth Sleepiness Scale (ESS), Mandibular advancement appliances (MAA)

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1845156/