CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Calculating Weighting Factors for Mixing Megavoltage Photon Beams to Achieve Desirable Dose Distribution in Radiotherapy

عنوان مقاله: Calculating Weighting Factors for Mixing Megavoltage Photon Beams to Achieve Desirable Dose Distribution in Radiotherapy
شناسه ملی مقاله: JR_JBPE-9-3_004
منتشر شده در در سال 1398
مشخصات نویسندگان مقاله:

M J Tahmasebi Birgani - Department of Radiation therapy and Medical Physics, Faculty of medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
N Chegeni - Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
M Tahmasbi - Department of Radiology Technology, Paramedicine Faculty, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
M Hazbavi - Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
S M Hoseini - Department of Radiation therapy, Faculty of medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

خلاصه مقاله:
Background: In radiotherapy, low-energy photon beams are better adapted to the treated volume, and the use of high-energy beams can reduce hot spots in the radiation therapy. Therefore, mixing low and high energies with different ratios can control the rate of hotspots, as well as the dose distribution of the target volume. Material and Methods: The percentage depth doses (PDDs) were calculated at various depths, by using a fitted double exponential equation. Then, using quality factor equation and PDD of a ۱۰×۱۰ cm۲ field, the amount of energy equivalent to each PDD and the value of weighting factors of ۶, ۱۸ MV energies were calculated to produce different energies. To validate the mathematical model, dosimetry of ۱۰ MV energy was used. For this purpose, PDDs and dose Profile of ۱۰ MV obtained from the mix were compared with ones obtained from the measurement Results: The value of weighting factor of ۶ MV energy required for the ۱۰ ×۱۰ cm۲ field to create dose distribution of ۱۵ MV energy using ۶ and ۱۸ MV energies was obtained as equal to ۰.۵۷. Comparison of percentage depth dose curves and dose profile shows good agreement with the practical measurements of ۱۰ MV for ۱۰×۱۰ cm۲ field using gamma index.Conclusion: The simultaneous use of high and low photon energies with different weighting factors to achieve desirable energy makes possible the treatment of tumors located at various depths without the need for different modes of energy in the accelerator leading to a decrease in the cost of the equipment and a safer treatment of the cancerous patients.

کلمات کلیدی:
Percentage depth dose, Weighting Factors, Mathematical Model, Dose Profile

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1892283/