CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

What can cause disbondment in three-layer pipe coating systems?

عنوان مقاله: What can cause disbondment in three-layer pipe coating systems?
شناسه ملی مقاله: IPPC01_137
منتشر شده در اولین کنفرانس لوله و صنایع وابسته در سال 1386
مشخصات نویسندگان مقاله:

Behrang Moeini - Islamic azad University (South of Tehran Branch Iran Engineering Inspection CO(I.E.I)

خلاصه مقاله:
Over the last few years, there have been many reported failures around the world in the adhesion of three-layer pipe coatings. It is debatable as to whether these adhesion failures put the pipeline at risk of corrosion, says Denis Grimshaw, of Jotun Powder Coatings A/S. However, many believe they must raise the potential for cathodic shielding. Failures fall into two main categories: adhesion failure between the FBE and the adhesive and the more serious failure between the FBE and the steel. Most failures between the FBE and the adhesive should be picked up in the standard plant quality assurance peel tests. These relate to the FBE being too reacted when the adhesive is applied, resulting in little or no bond between the FBE and the adhesive. However, some failures seen in the field relate to an aging effect, which cannot be detected in plant quality assurance testing. This is where the adhesive breaks down with the effect of water and heat, in a process known as hydrolysis.

کلمات کلیدی:
Adhesion,Pipeline,Cathodic Shielding

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/19146/