An Anthropomorphic Head Phantom Prototype for the Measurement of Geometric Distortion in Magnetic Resonance Imaging System

عنوان مقاله: An Anthropomorphic Head Phantom Prototype for the Measurement of Geometric Distortion in Magnetic Resonance Imaging System
شناسه ملی مقاله: JR_IJMP-21-1_007
منتشر شده در در سال 1403
مشخصات نویسندگان مقاله:

sadegh shurche - Physics and medical engineering Department, Medical Faculty, Tehran University of Medical Sciences, Tehran, Iran
Mohammad Yousefi sooteh - Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran

خلاصه مقاله:
Introduction: Our goal is to design and construct a new anthropomorphic head phantom for assessment of image distortion in treatment planning systems. Material and Methods: In this study, CT scan images of heads were transferred to the Mimic software. Using this software, the skull texture was removed and a hollow layer was formed between the bone tissues, in which the bone tissue would be equivalent to the material. Then it was fabricated with a ۳D printer using K۲HPO۴ (as bone). A new phantom containing ۸,۰۰۰ reference features (control points) with AutoCAD software designed, fabricated it with a ۳D printer and filled it with gels that included nickel-doped agarose, urea, and sodium chloride (as soft tissue) and then placed this grid inside the head phantom. This phantom was tested on the Siemens ۳ Tesla Prisma MRI model using a ۶۴-channel head coil. In this regard, a three-dimensional reference model was used. Reproducibility on the phantom was investigated with three different imaging sessions per day for three different days. Results: T۲ gel value, ۸۴.۸۰۴ ± ۳ms was obtained for gel that simulates brain tissue. In addition, their corresponding T۱ measurements were ۱۰۹۰.۹۲ (ms), respectively. By Adding nickel to agarose gels, the amount of CT number in all energies of ۸۰ to ۱۳۰ kVp increased. Increasing the concentration of nickel in gels results in a decrease in CT number. The geometric distortion in the ۳D results was found to be due to field non-uniformity and nonlinearity of the gradients and its reproducibility. Conclusion: The results show that, the amount of distortion in the middle of the field was less than that of its sides. This phantom can be used to check image distortion in treatment planning systems.

کلمات کلیدی:
Anthropomorphic Head Phantom Geometric Distortion High, field MRI