CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Radiographic Assessment of Bone Cortex to Bone Diameter Ratio of Radius, Tibia, Metacarpus, Metatarsus and Proximal Phalanx of Fore and Hindlimbs in Minature Donkey

عنوان مقاله: Radiographic Assessment of Bone Cortex to Bone Diameter Ratio of Radius, Tibia, Metacarpus, Metatarsus and Proximal Phalanx of Fore and Hindlimbs in Minature Donkey
شناسه ملی مقاله: JR_IJVS-10-2_006
منتشر شده در در سال 1394
مشخصات نویسندگان مقاله:

Mohammad Naser Nazem - Assistant Pro. of Department of Basic Sciences, Faculty of Veterinary Medicine, University of Shahid Bahonar, Kerman, Kerman, Iran
Ali Sadeghi - Under graduate student, Faculty of Veterinary Medicine, Shahid Bahonar University of Kerman, Kerman, Iran.
Ali Mostafavi - Department of clinical Sciences, Faculty of Veterinary Medicine, University of Shiraz, Shiraz, Iran.

خلاصه مقاله:
Objective - The aim of this study was to measure the ratio of bone cortex (C) to bone diameter (D), (C/D) in radius/tibia, metacarpus /metatarsus and proximal phalanges in fore and hindlimbs to be used as a diagnostic guide in metabolic and nutritional diseases in Minature Donkey. Design- Experimental study Animals- Eight adult Minature donkeys. Procedures- Lateromedial, dorsopalmar and dorsoplantar radiographs of eight fore and hindlimbs of Miniature donkeys were studied. Cortical thickness, bone diameter and C/D ratio of mid radius/tibia regions, mid metacarpal/metatarsal regions and mid proximal phalanx of forelimb/ mid proximal phalanx of hindlimb regions were measured. Data were analyzed statistically and mean, standard errors and P-values were obtained. Results- C/D ratios of mid radial region, mid metacarpal region and mid proximal phalanx of forelimb in lateromedial view were ۰.۵۴ ± ۰.۰۲, ۰.۵۸±۰.۰۲ and ۰.۵۴±۰.۰۳ respectively. C/D ratios of mid tibia region, mid metatarsal region and mid proximal phalanx of hindlimb in lateromedial view were ۰.۵۶±۰.۰۱, ۰.۶۵±۰.۰۲ and ۰.۵۴±۰.۰۵ respectively. C/D ratios of mid radial, mid metacarpal and mid proximal phalanx regions of forelimb in dorsopalmar view were ۰.۵۵±۰.۰۳, ۰.۶±۰.۰۱ and ۰.۵۵±۰.۰۲ respectively. C/D ratios of mid tibia, mid metatarsal and mid proximal phalanx regions of hindlimb in dorsoplantar views were ۰.۴۹±۰.۰۲, ۰.۵۷±۰.۰۲ and ۰.۵۵±۰.۰۴ respectively. Conclusion and Clinical Relevance- This study showed that there were no significant differences between C/D ratios in any of the regions. The cortex and diameter in lateromedial view between metacarpal – metatarsal regions and cortical thickness of proximal phalanx of forelimb - hindlimb regions showed significant difference (P<۰.۰۵).

کلمات کلیدی:
Radiography, Bone cortex to diameter Ratio, Forelimb, Hindlimb, Miniature Donkey

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1989626/