Seismic Retrofit of Rectangular Concrete Columns with Splice Deficiencies by External Prestressing

Publish Year: 1382
نوع سند: مقاله کنفرانسی
زبان: English
View: 2,095

This Paper With 8 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

SEE04_SS15

تاریخ نمایه سازی: 10 آبان 1384

Abstract:

Experimental research has been conducted to investigate the effectiveness of external prestressing as a seismic retrofit methodology for reinforced concrete bridge columns. The retrofit technique involves external prestressing concrete columns in transverse direction to improve their seismic performance.Rectangular columns with spliced longitudinal reinforcement have been tested with and without seismic retrofitting. It was observed that external prestressing improved bond between concrete and reinforcement in the splice region and resulted in improvements in inelastic column deformability. The paper outlines the experimental program employed and the test results obtained.

Authors

Majid Sadoughi Yarandi

Doctoral Candidate, Department of Civil Engineering, University of Ottawa, Ottawa, Canada

Murat Saatcioglu

Professor, Department of Civil Engineering, University of Ottawa, Ottawa, Canada,