Experimental stydy of the orifice plate with a cone swirler flow conditioner
عنوان مقاله: Experimental stydy of the orifice plate with a cone swirler flow conditioner
شناسه ملی مقاله: ISME13_547
منتشر شده در سیزدهمین کنفرانس سالانه مهندسی مکانیک در سال 1384
شناسه ملی مقاله: ISME13_547
منتشر شده در سیزدهمین کنفرانس سالانه مهندسی مکانیک در سال 1384
مشخصات نویسندگان مقاله:
Abolfazl Ahmadi - University Of Science and Technology-Arak Branch, University of Sheffield
Stephen Beck - University Of Science and Technology-Arak Branch, University of Sheffield
Hamid Abdi - University Of Science and Technology-Arak Branch, University of Sheffield
خلاصه مقاله:
Abolfazl Ahmadi - University Of Science and Technology-Arak Branch, University of Sheffield
Stephen Beck - University Of Science and Technology-Arak Branch, University of Sheffield
Hamid Abdi - University Of Science and Technology-Arak Branch, University of Sheffield
The sensitivity of orifice plate metering to poorly conditioned and swirling flows are subjects of concerns to flow meter users and manufacturers. The distortions caused by pipe fittings and pipe installations upstream of the orifice plate are major sources of this type of non-standard flows. These distortions will alter the accuracy of metering by up to 7% of the standard discharge coefficient, an unacceptable degree. So the design of orifice plate meters that are independent of the initial flow conditions of the upstream is a major object of flow metering. This goal is usually achieved using a flow conditioner. The work described here is the development of an orifice plate combined with swirler flow conditioner that is
broadly insensitive to upstream disturbances. The experimental results by using the new swirler flow conditioner shows this flow conditioner can attenuate the effect of both swirling and asymmetric flow on metering to an acceptable level.
کلمات کلیدی: orifice, asymmetric, swirling flow, swirler flow conditioner
صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/27152/