SINGLE-BLOW TEST FOR EVALUATION OF HEAT TRANSFER PERFORMANCE OF PERFORATED-PLATES
Publish place: 14th Annual Conference of Mechanical Engineering
Publish Year: 1385
نوع سند: مقاله کنفرانسی
زبان: English
View: 1,636
This Paper With 7 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
ISME14_469
تاریخ نمایه سازی: 1 فروردین 1386
Abstract:
The heat transfer and flow friction characteristics of perforated-plates are important factors in the design of a Matrix Heat Exchanger (MHE). No satisfactory theory exists to predict the overall heat transfer coefficient for a perforated-plate, and this coefficient must be measured under varying geometrical and operating parameters. We have developed analytical techniques to reduce the experimental data of single-blow transient test of discrete plate-spacer pairs. A single-blow transient test set up has been used to determine heat transfer coefficients of stacks of perforated-plates. The results are presented in terms of Nusselt number, given as function of Reynolds number and geometrical parameters.
Keywords:
Martrix Heat Exchanger – Perforated plates – Single blow Test - Maximum Slope - Heat Transfer Coefficient
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :