CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Humic acid removal from aqueous solutions by peroxi-electrocoagulation process

عنوان مقاله: Humic acid removal from aqueous solutions by peroxi-electrocoagulation process
شناسه ملی مقاله: JR_EHEM-2-2_002
منتشر شده در شماره ۲ دوره ۲ فصل Spring در سال 1394
مشخصات نویسندگان مقاله:

Ahmad Reza Yazdanbakhsh - Associate Professor, Department of Environmental Health Engineering, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Majid Kermani - Assistant Professor, Department of Environmental Health Engineering, Iran University of Medical Sciences, Tehran, Iran
Sanaz Komasi - MSc of Environmental Engineering, Department of Environmental Engineering, Islamic Azad University, West Tehran Branch, Tehran, Iran
Ehsan Aghayani - PhD Student, Department of Environmental Health Engineering, Tarbiat Modares University of Medical Sciences, Tehran, Iran

خلاصه مقاله:
Background: Natural organic matter is the cause of many problems associated with water treatment such as the presence of disinfection by-products (DBPs) and membrane fouling during water filtration. In this study, the performance of the peroxi-electrocoagulation process (PEP) was investigated for the removal of humic acids (HAs) from aqueous solutions.Methods: PEP was carried out for the removal of HA using a plexiglas reactor with a volume of 2 L and fitted with iron electrodes and a direct current supply (DC). Samples were taken at various amounts of pH (2-4), current density (1 and 2A/cm2), hydrogen peroxide (50-150 mg/L) and reaction time (5-20 minutes) and then filtered to remove sludge formed during reaction. Finally, the HA concentration was measured by UV absorbance at 254 nm (UV254).Results: Results indicated that increasing the concentration of H2O2 from 50 to 150 mg/L increased HA removal efficiency from 83% to 94.5%. The highest removal efficiency was observed at pH 3.0; by increasing the pH to the alkaline range, the efficiency of the process was reduced. It was found that HA removal efficiency was high in current density 1A/cm2. Increasing current density up to 1 A cm-2 caused a decrease in removal efficiency. Results of this study showed that under the optimum operating range for the process ([current density] = 1A/cm2, [hydrogen peroxide concentration] = 150 mg/L, [reaction time]= 20 minutes and [pH]= 3.0), HA removal efficiency reached 98%.Conclusion: It can be concluded that PEP has the potential to be utilized for cost-effective removal of HA from aqueous solutions.

کلمات کلیدی:
Humic acid, Peroxi-electrocoagulation, Iron electrode, UV254, Water solutions

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/488017/