CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Ultrasound detection of placenta accreta in the first trimester of pregnancy

عنوان مقاله: Ultrasound detection of placenta accreta in the first trimester of pregnancy
شناسه ملی مقاله: JR_IJRM-12-6_008
منتشر شده در شماره ۶ دوره ۱۲ فصل June در سال 1393
مشخصات نویسندگان مقاله:

Fatemeh Rahimi-Sharbaf - Perinatalogy Devision, Department of Obstetrics and Gynecology, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran
Ashraf Jamal - Perinatalogy Devision, Department of Obstetrics and Gynecology, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran
Elaheh MesdaghiniaP - Perinatalogy Devision, Department of Obstetrics and Gynecology, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran
Masoumeh Abedzadeh- Kalahroudi - Trauma Nursing Research Center, Kashan University of Medical Sciences, Kashan, Iran

خلاصه مقاله:
Background: Placenta accreta is considered a life-threatening condition and the main cause of maternal mortality. Prenatal diagnosis of placenta accreta usually is made by clinical presentation, imaging studies like ultrasound and MRI in the second and third trimester.Objective: To determine accuracy of ultrasound findings for placenta accreta in the first trimester of pregnancy.Materials and Methods: In a longitudinal study 323 high risk patients for placenta accreta were assessed. The eligible women were examined by vaginal and abdominal ultrasound for gestational sac and placental localization and they were followed up until the end of pregnancy. The ultrasound findings were compared with histopathological examinations as a gold standard. The sensitivity, specificity, positive and negative predictive value of ultrasound were estimated for the first trimester and compared with other 2 trimesters in the case of repeated ultrasound examination.Results: Ultrasound examinations in the first trimester revealed that 28 cases had the findings in favor of placenta accreta which ultimately was confirmed in 7 cases. The ultrasound sensitivity and specificity for detecting placenta accreta in the first trimester was 41% [95% CI: 16.2-62.7] and 88% [95% CI: 88.2-94.6] respectively.Conclusion: Ultrasound screening for placenta accreta in the first trimester of pregnancy could not achieve the high sensitivity as second and third trimester of pregnancy.

کلمات کلیدی:
Placenta accreta, Ultrasonography, Screening, Sensitivity, Specificity

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/489027/