Iron oxide nanoparticles modified carbon paste electrode as an effective electrochemical sensor for sensitive voltammetric determination of ascorbic acid

Publish Year: 1394
نوع سند: مقاله کنفرانسی
زبان: English
View: 282

متن کامل این Paper منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل Paper (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دریافت نمایند.

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

ELECTROCHEMISTRY011_171

تاریخ نمایه سازی: 5 بهمن 1395

Abstract:

This research describes the development and electrochemical utilization of iron oxide nanoparticles on a multi walled modified carbon paste electrode. The electrochemical behaviorof ascorbic acid on this modified electrode was studied using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The electrochemical profile of the prepared modified electrode by cyclic voltammetry showed a considerable shift of the oxidation peakpotential of ascorbic acid to less positive value and the anodic peak current was enhanced several times in comparison to the unmodified carbon paste electrode. The effect of some experimental parameters such as pH, scan rate, concentration of ascorbic acid and supporting electrolyte wereinvestigated. The results exhibited that the oxidation of ascorbic acid was irreversible and demonstrated diffusion controlled process depending on pH. At the optimum conditions, the concentration of ascorbic acid in 0.1 M phosphate buffer solution at pH 6.0 was performed byusing cyclic voltammetry in a linear range of 0.05 to 7.5 mM with a correlation coefficient of 0.997 and detection limit of 0.001 mM and using differential pulse voltammetry in a linear rangeof 0.05 to 7.5 mM with a correlati0n coefficient of 0.999. These results show that the modified carbon paste electrode has high sensitivity, reproducibility and repeatability. This electrode also used for determination of ascorbic acid in real samples.

Authors

Hamed Bagheri

Department of Chemistry, Faculty of Science, Kerman branch, Islamic Azad University, Kerman, Iran

Mahdiyeh Ghazizadeh

Department of Chemistry, Faculty of Science, Kerman branch, Islamic Azad University, Kerman, Iran

Hamideh Asadllahzadeh

Department of Chemistry, Faculty of Science, Kerman branch, Islamic Azad University, Kerman, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :