CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Electrochemical immunoassay based on a 96-well screen-printed ELISA plate

عنوان مقاله: Electrochemical immunoassay based on a 96-well screen-printed ELISA plate
شناسه ملی مقاله: ELECTROCHEMISTRY011_325
منتشر شده در یازدهمین سمینار سالانه الکتروشیمی ایران در سال 1394
مشخصات نویسندگان مقاله:

p Fanjul-Bolado - DropSens, S.L., Edificio CEEI, Parque Tecnológico de Asturias, 33428 Llanera, Asturias, Spain
M.M.P.S Neves - DropSens, S.L., Edificio CEEI, Parque Tecnológico de Asturias, 33428 Llanera, Asturias, Spain
M. B. González García - DropSens, S.L., Edificio CEEI, Parque Tecnológico de Asturias, 33428 Llanera, Asturias, Spain
d Hernández-Santos - DropSens, S.L., Edificio CEEI, Parque Tecnológico de Asturias, 33428 Llanera, Asturias, Spain

خلاصه مقاله:
In this work, a novel electrochemical based-immunoassay for the specific detection of biomarkers employing a 96-well screen-printed microplate as the transducer surface, wasdeveloped. The capture element of the proposed sandwich immunoassay was efficiently immobilized onto the surface of the 96-well array and different concentrations of biomarkers, within a range of clinical interest, were assayed. The detection of the analyte of interest wasaccomplished by using alkaline phosphatase (AP) as the enzymatic label. The analytical signal was obtained by using two AP enzymatic substrates: 3-indoxyl phosphate/silver ions (3-IP/Ag+) [2] and the new hydroquinone diphosphate/silver ions (HQDP/Ag+), which results werecompared, namely in terms of sensitivity. In both cases, a biometallization process, where the enzymatic reaction gives rise to a compound that reduces silver ions in solution into a metallic deposit, took place. Thus, the silver enzymatically deposited on the electrode surface wasdetected through the oxidation peak of the silver when an anodic stripping scan was carried out. Moreover, different methodologies for the modification, in a reproducible manner, of this 96-well screen-printed electrochemical array, were studied. Therefore, the ELISA plate surface was modified with carbon nanotubes (CNTs), gold nanoparticles (GNPs) and with a hybrid conjugation of these carbon-metal nanomaterials (CNTs-GNPs). The reproducibility, stabilityand biofuncionality of these nanostructed transducer surfaces were also evaluated. The electrochemical behaviour of this immunosensor was carefully evaluated assessing aspects as sensitivity, non-specific binding, limits of detection and reproducibility and the analytical figures of merit were obtained

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/546528/