Investigation of the effects of hot tube geometry on the efficiency of vortex tube refrigerators base on FVM analysis

Publish Year: 1396
نوع سند: مقاله کنفرانسی
زبان: English
View: 649

This Paper With 19 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

ICET01_018

تاریخ نمایه سازی: 13 شهریور 1396

Abstract:

In this article, a Ranque–Hilsch Vortex Tube has been optimized utilizing divergence and convergence axial angles for hot tube. Effect of divergence and convergence angles on the flow behavior has been investigated by computational fluid dynamics (CFD) techniques. By using a RNG k-ԑ turbulence model based on finite volume method, all the computations have been carried out. The dimensions of the studied vortex tubes have been kept the same for all models and the performance of machine was studied under five different divergence angles ( α ), namely 1, 2, 3, 4 and 6 degree, two different convergence angles named 1 and 2 degree adjusted to the hot tube. Achieving a minimum cold exit temperature is the main goal of this numerical research. The results show that utilizing the divergent kind of hot tube improves the cooling capacity of device for most values of inlet mass flow rates. Finally, some results of the CFD models have been validated by the available experimental and numerical data and which show reasonable agreement, and other ones are compared qualitatively.

Keywords:

Authors

Adib Bazgir

B.sc chemical engineering at Petroleum University of technology, Ahwaz, Iran