VOC level control by ventilation improvement of Flexography printing room using CFD modeling

Publish Year: 1396
نوع سند: مقاله ژورنالی
زبان: English
View: 546

This Paper With 7 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_JACM-3-3_002

تاریخ نمایه سازی: 1 اردیبهشت 1397

Abstract:

Using Computational Fluid Dynamics (CFD) technique, the dispersion contours and the exposure rate of Flexographic printing workers to VOCs in a printing department is evaluated. Firstly, VOCs distribution is determined in the printing room due to the existing ventilation system. Through next steps, 4 scenarios for lowering VOCs concentration and its exposure rate to workers are analyzed. Concentration distributions of ethylene glycol (MEG) as a representative of VOCs are determined for 4 scenarios. The results show that, regarding the existing ventilation, the concentration of MEG at the breathing height is 1×10-5 mg/m3 and it is higher than the standard permissible level. Finally, the findings of this study lead to lowered VOCs concentrations to 13.87×10-9 mg/m3 via changing the ventilation system for the Flexography Printing Room

Authors

Kamal Hadad

School of Mechanical Engineering, Shiraz University, Shiraz, Iran

Hamid Reza Eidi

Printing Management, International Imam Reza University, Mashhad, Iran