CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Appropriate location for fission chamber detector in Tehran Research Reactor

عنوان مقاله: Appropriate location for fission chamber detector in Tehran Research Reactor
شناسه ملی مقاله: ICELE03_151
منتشر شده در سومین کنفرانس بین المللی مهندسی برق در سال 1397
مشخصات نویسندگان مقاله:

Mohsen Ahmadnia - Assistant professor, Department of Electrical Engineering, Hakim Sabzevari University, Sabzevar, Iran

خلاصه مقاله:
In this work, the fission chamber detector with 5 MW of power had tested in different locations of TehranResearch Reactor pool. If the detector was located at the distance of 1 meter from the eastern edge of the reactor and atthe height of about 1.4 meters from the floor, it were the best location for detector counting but due to the differentplacements and displacements in western part of the reactor, it was not possible unfortunately. The dead time for 3 MWof power had been 1.67% which was the best result in comparison with Monte Carlo Code.

کلمات کلیدی:
Linear Behavior, Dead Time, Multichannel Analyzer (MCA), Feed Preamplifier

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/831648/