Investigation of Zeolitic Imidazolate Frameworks Ability as Sorbent in Stir Bar Sorptive Extraction Method

Publish Year: 1397
نوع سند: مقاله کنفرانسی
زبان: English
View: 268

متن کامل این Paper منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل Paper (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دریافت نمایند.

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

IRANCC20_535

تاریخ نمایه سازی: 28 اردیبهشت 1398

Abstract:

In this work, the zeolite imidazole framework-8 (ZIF-8) was initially synthesized by the solvothermal method. After confirmation of its structure, it was used to provide a new composite of acrylate-based polymer (PA) and ZIF-8 as a coating on a stir bar with suitable mechanical and chemical stability. Different manipulation methods was used for this purpose. This monolithic coated (PA/ZIF-8) devise was used in a stir bar sorptive extraction (SBSE) method. During the preparation of PA/ZIF-8 coating, the solvent type, the monomer to the solvent ratio, the monomer to cross linker ratio and the amount of ZIF-8 powder were optimized. In the optimization process, carvedilol (CAR) was used as a target compound and the extraction efficiency of this drug using proposed SBSE method was investigated by high performance liquid chromatography (HPLC) with photo diode array detector (PDA). In all steps, PA coated stir bar was also prepared for comparison of its extraction efficiency with PA/ZIF-8 coated stir bar. ). Repeatability in the production of ZIF-8/PA sorption coating on the stir bar was determined by calculating the relative standard deviation (RSD) of the extracted carvedilol field surface with three stir bar in a batch and in three different batch 6.6% and 6.96%, respectively. In order to investigate ability of optimized PA/ZIF-8 and PA coatings, haloperidol (HLP), losartan (LOS), loratadine (LOR), diazepam (DZ), nordiazepam (NDZ) and chlorpromazine (CPZ) were also tested as target compounds and their extraction efficiency were obtained. The results showed that HLP, LOS, LOR, DZ and NDZ are extracted on PA/ZIF-8 and PA coated stir bars at similar extraction and desorption conditions. But in the case of CAR and HLP, the use of PA/ZIF-8 stir bar showed an improvement of 100% in the concentration factor obtained from PA stir bar.Finally, effective parameters on extraction efficiency of CAR and HLP such as pH and volume of sample, extraction and desorption time and type of desorption solvent were optimized. Then the proposed method (monolithic PA/ZIF-8 coated-SBSE-HPLC-PDA) was validated and used for determination of CAR and HLP in human plasma samples.

Authors

Zahra Nasrollahi Khoshkbar

Department of Chemistry, Faculty of the Physics and Chemistry, Alzahra University, Tehran, Iran

Zahra Talebpour

Department of Chemistry, Faculty of the Physics and Chemistry, Alzahra University, Tehran, Iran

Sima Najafi Ghamat

Department of Chemistry, Faculty of the Physics and Chemistry, Alzahra University, Tehran, Iran