A comparison of 2D and 3D kidney absorbed dose measures in patients receiving 177Lu-DOTATATE

Publish Year: 1397
نوع سند: مقاله ژورنالی
زبان: English
View: 279

This Paper With 7 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_JNMB-6-2_005

تاریخ نمایه سازی: 12 تیر 1398

Abstract:

Objective(s): To investigate and compare quantitative accuracy of kidney absorbed dose measures made from both 2D and 3D imaging in patients receiving 177LuDOTATATE (Lutate) for treatment of neuroendocrine tumours (NETs). Methods: Patients receiving Lutate therapy underwent both whole body planar imaging and SPECT/CT imaging over the kidneys at time points 0.5, 4, 24, and 96-120 hours after injection. Planar data were corrected for attenuation using transmission data, and were converted to units of absolute activity via two methods, using either a calibration standard in the field of view or relative to pre-voiding image total counts. Hand drawn regions of interest were used to generate time activity curves and kidney absorbed dose estimates in OLINDA-EXM. Fully quantitative SPECT data were generated using CT-derived corrections for both scatter and attenuation, before correction for dead time and application of a camera specific sensitivity factor to convert data to units of absolute activity. Volumes of interest were defined for kidney using the co-registered x-ray CT, before time activity curves and absorbed dose measures were generated in OLINDA-EXM, both with and without corrections made to the model for patient specific kidney volumes. Quantitative SPECT data were also used to derive dose maps through dose kernel convolution (DKC), which was treated as the gold standard. Results: A total of 50 studies were analysed, corresponding to various cycles of treatment from 21 patients. Planar absorbed dose estimates were consistently higher than SPECT derived estimates by, on average, a factor of 3. Conclusion: Quantitative SPECT is considered the gold standard approach for organ specific dosimetry however often relies on in house software. As such planar methods for estimating absorbed dose are much more widely available, and in particular, are often the only source of reference in previously published data. For the case of Lutate dosimetry, planar measures may lead to a three-fold increase in measures of kidney absorbed dose.

Authors

Kathy Willowson

Institute of Medical Physics, The University of Sydney

HyunJu Ryu

Faculty of Health Sciences, University of Sydney, Lidcombe ۲۱۴۱, Australia

Price Jackson

Department of Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne ۳۰۰۰, VIC, Australia

Enid Eslick

Institute of Medical Physics, School of Physics, University of Sydney, ۲۰۰۶ NSW, Australia

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Sandstrom M, Garske U, Granberg D, Sundin A, Lundqvist H. ...
  • Valkema R, Pauwels SA, Kvols LK, Kwekkeboom DJ, Jamar F, ...
  • Cremonesi M, Ferrari M, Bodei L, Tosi G, Paganelli G. ...
  • Emami B, Lyman J, Brown A, Coia L, Goitein M, ...
  • Bodel L, Cremonesi M, Ferrari M, Pacifici M, Grana CM, ...
  • Kwekkeboom DJ, Bakker WH, Kooij PP, Konijnenberg MW, Srinivasan A, ...
  • Wehrmann C, Senftleben S, Zachert C, Muller D, Baum RP. ...
  • Garkavij M, Nickel M, Sjogreen-Gleisner K, Ljunberg M, Ohlsson T, ...
  • Pauwels S, Barone R, Walrand S, Borson-Chazot F, Valkema R, ...
  • Heikkonen J, Mäenpää H, Hippeläinen E, Reijonen V, Tenhunen M. ...
  • Ljunberg M, Celler A, Konijnenberg MW, Eckerman K, Dewaraja YK, ...
  • Bailey D, Hennessy T, Willowson K, Schembri G, Roach P, ...
  • Aslani A, Snowdon GM, Bailey DL, Schembri GP, Bailey EA, ...
  • Siegel JA, Thomas SR, Stubbs JB, Stabin MG, Hays MT, ...
  • Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal ...
  • Willowson K, Bailey DL, Baldock C. Quantitative SPECT reconstruction using ...
  • Jackson PA, Beauregard JM, Hofman MS, Kron T, Hogg A, ...
  • نمایش کامل مراجع