CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Evaluation of the Possible Utilization of 68Ga-DOTATOC in Diagnosis of Adenocarcinoma Breast Cancer

عنوان مقاله: Evaluation of the Possible Utilization of 68Ga-DOTATOC in Diagnosis of Adenocarcinoma Breast Cancer
شناسه ملی مقاله: JR_JNMB-6-1_006
منتشر شده در شماره 1 دوره 6 فصل در سال 1397
مشخصات نویسندگان مقاله:

Hassan Yousefnia - Nuclear Science and Technology Research Institute (NSTRI)
mojdeh naderi - University of Zanjan , Zanjan, Iran, Postal Code: ۴۵۳۷۱۳۸۷۹۱
samaneh zolghadri - nuclear science and technology research institute
Behrooz Alirezapour - nuclear science and technology research institute

خلاصه مقاله:
Objective(s): Studies have indicated advantageous properties of [DOTA-DPhe1 , Tyr3 ] octreotide (DOTATOC) in tumor models and labeling with gallium. Breast cancer is the second leading cause of cancer mortality in women, and most of these cancers are often an adenocarcinoma. Due to the importance of target to non-target ratios in the efficacy of diagnosis, the pharmacokinetic of 68Ga-DOTATOC in an adenocarcinoma breast cancer animal model was studied in this research, and the optimized time for imaging was determined. Methods: 68Ga was obtained from 68Ge/68Ga generator. The complex was prepared at optimized conditions. Radiochemical purity of the complex was checked using both HPLC and ITLC methods. Biodistribution of the complex was studied in BALB/c mice bearing adenocarcinoma breast cancer. Also, PET/CT imaging was performed up to 120 min post injection. Results: The complex was produced with radiochemical purity of greater than %98 and specific activity of about 40 GBq/mM at optimized conditions. Biodistribution of the complex was studied in BALB/c mice bearing adenocarcinoma breast cancer indicated fast blood clearance and significant uptake in the tumor. Significant tumor:blood and tumor:muscle uptake ratios were observed even at early times postinjection. PET/CT images were also confirmed the considerable accumulation of the tracer in the tumor. Conclusion: Generally, the results proved the possible application of the radiolabelled complex for the detection of the adenocarcinoma breast cancer and according to the pharmacokenitic data, the suitable time for imaging was determined as at least 30 min after injection.

کلمات کلیدی:
Adenocarcinoma breast cancer, Gallium-68, PET/CT imaging

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/887419/