CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

The Efficiency of Respiratory-gated 18F-FDG PET/CT in Lung Adenocarcinoma: Amplitude-gating Versus Phase-gating Methods

عنوان مقاله: The Efficiency of Respiratory-gated 18F-FDG PET/CT in Lung Adenocarcinoma: Amplitude-gating Versus Phase-gating Methods
شناسه ملی مقاله: JR_JNMB-5-1_004
منتشر شده در شماره 1 دوره 5 فصل در سال 1396
مشخصات نویسندگان مقاله:

Yoshiyuki Kitamura - Department of Clinical Radiology, Kyushu University Hospital, Fukuoka, Japan
Shingo Baba - Department of Clinical Radiology, Kyushu University Hospital, Fukuoka, Japan
Takuro Isoda - Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
Yasuhiro Maruoka - Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan

خلاصه مقاله:
Objective(s): In positron emission tomography (PET) studies, thoracic movement under free-breathing conditions is a cause of image degradation. Respiratory gating (RG) is commonly used to solve this problem. Two different methods, i.e., phase-gating (PG) and amplitude-gating (AG) PET, are available for respiratory gating. It is important to know the strengths and weaknesses of both methods when selecting an RG methodfor a given patient. We conducted this study to clarify whether AG or PG is preferable for measuring fluorodeoxyglucose (FDG) accumulation in lung adenocarcinoma and to investigate patient conditions which are most suitable for AG and PG methods.Methods: A total of 31 patients (11 males, 20 females; average age: 11.6±70.1 yrs) with 44 lung lesions, diagnosed as lung adenocarcinoma between April 2012 and March 2013, were investigated. Whole-body FDG-PET/CT scan was performed with both PG and AG methods in all patients. The maximum standardized uptake value (SUVmax) of PG, AG, and the control data of these two methods were measured, and the increase ratio (IR), calculated as IR(%)= (Post – Pre)/Pre × 100, was calculated. The diameter and positionof lung lesions were also analyzed. We defined an ‘effective lesion’ of PG (or AG) as a lesion which showed a higher IR compared to AG (or PG). 8 (25.8%)Results: The average SUVmax and average IR were 7.94±8.99 and 25.6±21.4% in PG and 6.70±7.60 and 14.4±4.0% in AG, respectively. Although there was no significant difference between the average SUVmax of PG and AG (P=0.09), the average IR of PG was significantly higher than that of AG (P<0.01). The number of PG- and AG-effective lesions was 32 (72.7%) and 12 (28.3%) , respectively. There was no significant difference in the average diameter or position of the lesions between the PG- and AG-effective lesions.There were 23 (74.2%) PG-effective and 8 (25.8%) AG-effective patients. No significant difference was observed in sex or age between PG- and AG-effective patients.Conclusion: The PG method was more effective for measuring FDG accumulation of lung lesions under free-breathing conditions in comparison with the AG method.

کلمات کلیدی:
FDG-PET/CT, Lung adenocarcinoma, Positron Emission Tomography, Respiratory gating

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/887439/