Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

عنوان مقاله: Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET
شناسه ملی مقاله: JR_JNMB-2-2_004
منتشر شده در شماره 2 دوره 2 فصل در سال 1393
مشخصات نویسندگان مقاله:

Hyeon Sik Kim - Department of Nuclear Medicine, Chonnam National University Hwasun Hospital, Hwasun-Gun, Jeollanamdo, South Korea
Sang-Geon Cho - Department of Nuclear Medicine, Chonnam National University Hospital, Hwasun-Gun, Jeollanamdo, South Korea
Ju Han Kim - Department of Cardiology, Chonnam National University Hospital, Hwasun-Gun, Jeollanamdo, South Korea
Seong Young Kwon - Department of Nuclear Medicine, Chonnam National University Hwasun Hospital, Hwasun-Gun, Jeollanamdo, South Korea

خلاصه مقاله:
Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; age: 57, 53, and 76 years) were reconstructed, using filtered back projection (FBP) and ordered subset expectation maximization (OSEM) methods. OSEM reconstruction consisted of OSEM_2I, OSEM_4I, and OSEM_6I with 2, 4, and 6 iterations, respectively. The images, reconstructed and filtered by Gaussian filters of 5, 10, and 15 mm, were obtained, as well as non-filtered images. Visual analysis of image quality (IQ) was performed using a 3-grade scoring system by 2 independent readers, blinded to the reconstruction and filtering methods of stress images. Then, signal-to-noise ratio (SNR) was calculated by noise and contrast recovery (CR). Stress and rest MBF and coronary flow reserve (CFR) were obtained for each method. IQ scores, stress and rest MBF, and CFR were compared between the methods, using Chi-square and Kruskal-Wallis tests. Results: In the visual analysis, IQ was significantly higher by 10 mm Gaussian filtering, compared to other sizes of filter (PP=0.923 and 0.855 for readers 1 and 2, respectively). SNR was significantly higher in 10 mm Gaussian filter. There was a significant difference in stress and rest MBF between several vascular territories. However CFR was not significantly different according to various filtering methods. Conclusion: Post-reconstruction Gaussian filtering with a filter size of 10 mm significantly enhances the IQ of N-13 ammonia PET-CT, without changing the results of CFR calculation. .

کلمات کلیدی:
Gaussian filtering, Myocardial blood flow, PET image reconstruction