CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Comparison of the Impacts of Auriculotherapy with Electrical Stimulation and Vaccaria Seeds on Colposcopy Pain: A Randomized Clinical Trial

عنوان مقاله: Comparison of the Impacts of Auriculotherapy with Electrical Stimulation and Vaccaria Seeds on Colposcopy Pain: A Randomized Clinical Trial
شناسه ملی مقاله: JR_EBCJ-7-4_006
منتشر شده در شماره 4 دوره 7 فصل در سال 1397
مشخصات نویسندگان مقاله:

Samaneh Jouya - MSc Student of Midwifery, School of Nursing and Midwifery, Mashhad University of Medical Sciences, Mashhad, Iran
Nahid Golmakani - Assistant Professor, Department of Midwifery, Evidence-based Health Care Research Center, School of Nursing and Midwifery, Mashhad University of Medical Sciences, Mashhad, Iran
Seyed Reza Mazloum - Instructure, Evidence-based Caring Research Center, Department of Medical Surgical Nursing, School of Nursing and Midwifery, Mashhad University of Medical Sciences, Mashhad, Iran
Hamid Abdi - Assistant Professor, Department of Chinese Traditional Medicine, School of Complementary and Persian Traditional Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

خلاصه مقاله:
Background: Colposcopy is an invasive medical procedure, which involves pain and discomfort. Auriculotherapy is a medical technique that can facilitate the reduction of pain. Aim: The aim of this study was to compare the impacts of auriculotherapy with electrical stimulation and Vaccaria seeds on colposcopy pain. Method: This controlled randomized, clinical trial was conducted on 93 females undergoing colposcopy in Ghaem Hospital, Mashhad, Iran, in 2017. The study population was selected through convenience sampling technique, and then randomly assigned into three groups, namely transcutaneous auricular stimulation (TAS), Vaccaria seeds, and placebo. The TAS group was subjected to electrical stimulation at four auricular acupuncture points 40 min before colposcopy, using a Pointer Excel stimulator (2 Hz). In the Vaccaria seed group, the seeds were fixed on the same acupoints three days prior to colposcopy. The participants were asked to press each point for 1 min, three times a day. The placebo group were provided with three adhesive patches without any seeds. After colposcopy, pain intensity was monitored using the visual analog scale. Data analysis was performed using Kruskal-Wallis and exact Chi-square tests in SPSS software, version 22. Results: The three groups were comparable in terms of the demographic data (P> 0.05). The mean pain intensities in theTAS, seed, and placebo groups were 49.0±24.2, 49.5±26.0, and 65.1±26.6, respectively. A significant difference was observed among the three groups regarding the pain intensity (P=0.02). There were also significant differences between the TAS and placebo groups (P=0.01) and between seed and placebo groups in this respect (P=0.02). However, the TAS and seed groups showed no significant difference in this regard (P=0.94). Implications for Practice: The use ofauriculotherapy with TAS and seeds could effectively reduce the patient’s pain during colposcopy.

کلمات کلیدی:
Auriculotherapy, Colposcopic Biopsies, Colposcopy, Electrical Stimulation, Pain

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/889216/