Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures
عنوان مقاله: Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures
شناسه ملی مقاله: JR_TABO-5-5_003
منتشر شده در شماره 5 دوره 5 فصل در سال 1396
شناسه ملی مقاله: JR_TABO-5-5_003
منتشر شده در شماره 5 دوره 5 فصل در سال 1396
مشخصات نویسندگان مقاله:
Ali Andalib - Alzahra Hospital, Isfahan University of Medical Science, Isfahan, Iran
Erfan Sheikhbahaei - Isfahan University of Medical Sciences, Isfahan, Iran
Zeynab Andalib - Azad Islamic University, Najaf Abad branch, Isfahan, Iran
Mohammad A. Tahririan - Alzahra Hospital, Isfahan University of Medical Science, Isfahan, Iran
خلاصه مقاله:
Ali Andalib - Alzahra Hospital, Isfahan University of Medical Science, Isfahan, Iran
Erfan Sheikhbahaei - Isfahan University of Medical Sciences, Isfahan, Iran
Zeynab Andalib - Azad Islamic University, Najaf Abad branch, Isfahan, Iran
Mohammad A. Tahririan - Alzahra Hospital, Isfahan University of Medical Science, Isfahan, Iran
Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were operated with MIPO method in thiscross-sectional study at Alzahra university hospital in 2015. Eleven patients were excluded due to lack of adequatefollow-ups. Patients’data including union time; infection in the fractured site; hip and knee range of motion; and anymalunion or deformities like limb length discrepancy were collected after the surgery in every session.Results: Among 32 femoral and 17 tibial fractures, union was completed in48 patients, while only one patient withfemoral fracture had nonunion. The mean union time was 18.57±2.42 weeks. Femur fractures healed faster than tibia(17.76±2.36 compared to 19±2.37 weeks, respectively, P=0.09). None of the patients suffered from infections or fistula.The range of motion in hip and knee remained intact in approximately all patients. Malunion happened in 3 patients; 100internal rotation in 1 patient; and 1cm limb shortening in 2 patients.Conclusion: According to the result of this study, MIPO is a simple and effective method of fixation with a high rateof union as well as minimal complications for comminuted fractures of long bones. Infection is rare, and malunion orany deformity is infrequent. MIPO appears to be a promising and safe treatment alternative for comminuted fractures.
کلمات کلیدی: Comminuted fractures, Femur, Minimally invasive plate osteosynthesis, MIPO, Plate osteosynthesis, Tibia
صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/891319/