Optimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations
Publish place: Iranian Journal of Medical Physics، Vol: 15، Issue: 1
Publish Year: 1397
نوع سند: مقاله ژورنالی
زبان: English
View: 211
This Paper With 11 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-15-1_005
تاریخ نمایه سازی: 18 تیر 1398
Abstract:
IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization involved ninety physically abled patients aged between 20 to 60 years and weighed between 60 and 80 kilograms for four common digital radiographic examinations. Kerma X_plus, DAP meter was utilized to measure the entrance surface dose (ESD) while effective dose (ED) was estimated using CALDose_X 5.0 Monte Carlo software. The second phase, an experimental study utilized an anthropomorphic phantom (PBU-50) and Leeds test object TOR CDR for relative comparison of image quality. For the optimization phase, the imaging parameters with acceptable image quality and lowest ESD from the experimental study was related to patient’s body thickness. Image quality were evaluated by two radiologists using the modified evaluation criteria score lists. ResultsSignificant differences were found for image quality for all examinations. However significant difference for ESD were found for PA chest and AP abdomen only. The ESD for three of the examinations were lower than all published data. Additionally, the ESD and ED obtained for all examinations were lower than that recommended by radiation regulatory bodies. ConclusionOptimization of image quality and dose was achieved by utilizing an appropriate tube potential, calibrated automatic exposure control and additional filtration of 0.2mm copper.
Keywords:
Authors
Soo-Foon Moey
International Islamic University Malaysia
Zubir Shazli
International Islamic University Malaysia
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :