Determination of Dose-Equivalent Response of A Typical Diamond Microdosimeter in Space Radiation Fields
Publish place: Iranian Journal of Medical Physics، Vol: 15، Issue: 1
Publish Year: 1397
نوع سند: مقاله ژورنالی
زبان: English
View: 222
This Paper With 9 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-15-1_006
تاریخ نمایه سازی: 18 تیر 1398
Abstract:
Introduction: Microdosimeters are helpful for dose equivalent measurement in unknown radiation fields. The favorable physical and mechanical properties of the detector-grade chemical vapor deposition diamond materials have made the diamond microdosimeters suitable candidate for radioprotection applications in space. The purpose of this work is the investigation of the dose equivalent response of a typical diamond microdosimeter with laser-induced graphitized electrodes for use in space radiation fields.
Materials and Methods: The Geant4 Monte Carlo simulation toolkit was applied to simulate the particle transport within the microdosimeter, and to determine the mean chord length and the dose equivalent response of the microdosimeter, based on the lineal energy dependent quality factor.
Results: The linear stopping power of the protons and alpha particles with energies higher than 5 MeV and 10 MeV respectively can be estimated within20% of deviation using the microdosimeter response. The fluence to dose equivalent conversion coefficients calculated affirms that there is an adequate agreement between the calculated coefficients and other research group results.
Conclusion: The reasonable agreement between the dose equivalents calculated in this study and the results reported by other researchers confirmed that this type of microdosimeter could be a promising candidate suitable for the measurement of the dose equivalent in space radiation fields.
Keywords:
Authors
firouz payervand
Radiation Applications Research School, Nuclear Science and Technology Research Institute, AEOI, Tehran, Iran
Gholamreza Raisali
Radiation Applications Research School, Nuclear Science and Technology Research Institute, AEOI, P.O.Box: ۱۱۳۶۵-۳۴۸۶, Tehran, Iran
fereshte Hajiesmaeilbaigi
Laser and Optics Research School, Nuclear Science and Technology Research Institute, AEOI, P.O.Box: ۱۱۳۶۵-۸۴۸۶, Tehran, Iran
shahyar Saramad
Energy Engineering and Physics Faculty, Amirkabir University of Technology, P.O.Box: ۱۵۸۷۵-۴۴۱۳, Tehran, Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :