Estimation of Anti-dengue Phytochemical Markers Gallic acid, Rutin and Quercetin in Methanolic Extract of Euphorbia hirta (L.) and Tawa-Tawa Capsule Formulation by Validated RP-HPLC Method
عنوان مقاله: Estimation of Anti-dengue Phytochemical Markers Gallic acid, Rutin and Quercetin in Methanolic Extract of Euphorbia hirta (L.) and Tawa-Tawa Capsule Formulation by Validated RP-HPLC Method
شناسه ملی مقاله: JR_CHM-3-1_004
منتشر شده در شماره 1 دوره 3 فصل در سال 1398
شناسه ملی مقاله: JR_CHM-3-1_004
منتشر شده در شماره 1 دوره 3 فصل در سال 1398
مشخصات نویسندگان مقاله:
A Suganthi - Department of Pharmaceutical Analysis, College of Pharmacy, Sri Ramakrishna Institute of Paramedical Sciences affiliated to The Tamilnadu Dr. M.G.R. Medical University,۳۹۵, Sarojini Naidu Road, Coimbatore-۶۴۱ ۰۴۴
Ravi T.K - Department of Pharmaceutical Analysis, College of Pharmacy, Sri Ramakrishna Institute of Paramedical Sciences affiliated to The Tamilnadu Dr. M.G.R. Medical University,۳۹۵, Sarojini Naidu Road, Coimbatore-۶۴۱ ۰۴۴
خلاصه مقاله:
A Suganthi - Department of Pharmaceutical Analysis, College of Pharmacy, Sri Ramakrishna Institute of Paramedical Sciences affiliated to The Tamilnadu Dr. M.G.R. Medical University,۳۹۵, Sarojini Naidu Road, Coimbatore-۶۴۱ ۰۴۴
Ravi T.K - Department of Pharmaceutical Analysis, College of Pharmacy, Sri Ramakrishna Institute of Paramedical Sciences affiliated to The Tamilnadu Dr. M.G.R. Medical University,۳۹۵, Sarojini Naidu Road, Coimbatore-۶۴۱ ۰۴۴
Sensitive and precise RP-HPLC method with photo diode array detector has been developed and validated for the simultaneous estimation of three commonly available anti-dengue, anti-cancer and anti-inflammatory phytochemical markers. The chromatographic separation was achieved using C18 column (250 mm × 4.0 mm, 5μm) with 0.2% v/v formic acid: acetonitrile (50:50; v/v) as mobile phase at the flow rate of 0.7 mL/min. The dual wavelength (280 and 360 nm) was selected for the identification and quantification of rutin, gallic acid and quercetin (Rt 2.56, 2.95 and 4.60 min). The method was validated as per ICH guidelines in terms of specificity, linearity, precision, and accuracy, LOD and LOQ, respectively. Linearity range for the selected markers, gallic acid, rutin and quercetin was found to be 1–10 µg/mL with the correlation coefficient value close to 1. The sensitivity of the method was demonstrated from the limit of detection which was found to be 0.4 µg/mL for gallic acid; 0.3 µg/mL for rutin and quercetin. The limit of quantification for gallic acid, rutin and quercetin was found to be 1 µg/mL, respectively. The % RSD and recovery values prove that the developed method was more precise and accurate. Hence, the proposed validated method has been successfully applied for the quality control analysis of gallic acid, rutin and quercetin in methanolic extract of Euphorbia hirta (L.) and Tawa-Tawa capsule formulation.
کلمات کلیدی: RP-HPLC, Euphorbia hirta (L.), Gallic acid, Rutin, Quercetin, Methanolic extract
صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/895247/