CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Generating a Homogeneous Dose Distribution in the Junction Region between Two Adjacent Fields in Electron Beam Therapy

عنوان مقاله: Generating a Homogeneous Dose Distribution in the Junction Region between Two Adjacent Fields in Electron Beam Therapy
شناسه ملی مقاله: JR_IJMP-7-3_005
منتشر شده در شماره 3 دوره 7 فصل در سال 1389
مشخصات نویسندگان مقاله:

Mohammad Javad Tahmasebi Birgani - Associate Professor, Medical Physics & Radiotherapy Dept., Golestan Hospital, Ahwaz University of Medical Sciences, Ahwaz, Iran
Mohammad Ali Behrooz - Professor, Medical Physics Dept., Ahwaz University of Medical Sciences, Ahwaz, Iran
Hadi Keivan - M.Sc. Medical Physics Dept., Faculty of Medicine, Ahwaz University of Medical Sciences, Ahwaz, Iran

خلاصه مقاله:
Introduction: Treatment with megavoltage electron beams is ideal for irradiating superficial tumors because of their limited range in tissues. However, for electron treatment of extended areas, such as the chest wall, two or more adjacent fields can be used. Abutment of these fields may lead to significant dose in homogeneities in the junction region. The aim of this study is to offer a new method for generating a homogeneous dose distribution in the junction region between two adjacent fields in electron beam therapy. Materials and Methods: Several approaches have been proposed to solve the problem of ‘hot’ and ‘cold’ spots in the junction region between abutting electron fields. These techniques are based on beam-edge modifying devices or penumbra generators which act to broaden the electron beam penumbra, and thus facilitate field matching. But use of these devices is time consuming and design of the modifications to the applicators are generally applicator dependent. An idea which was originally proposed for matching two adjacent photon fields (with dose inhomogeneity of about ۲%) is resurrected here. This method is based on the rotation of the gantry such that the adjacent fields have a common edge and the overlap region in treatment volume is eliminated. For this purpose, the effective source to surface distance (SSDeff) for the available electron beam energies (۶, ۹, ۱۲ and ۱۵ MeV) and applicators (cones) (۶ × ۶, ۱۰ × ۱۰, ۱۵ ×۱۵, ۲۰ × ۲۰ and ۲۵ × ۲۵ cm۲) have been determined for a Varian ۲۱۰۰C linear accelerator. Result: Using SSDeff, in respect to beam divergence, one can use the photon beam behavior for electron beams and achieve a uniform dose distribution in adjacent electron fields. Discussion and Conclusion: Compared to beam-edge modifying devices or penumbra generators that are usually time consuming to plan and set up, rotating the gantry to eliminate the overlap region is simple and applicable in the problem of abutting electron fields. 

کلمات کلیدی:
Adjacent Electron Fields, SSDeff, Isodose Curve, Linear Accelerator

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/942389/