A reversed-phase high performance liquid chromatography approach for analysis of 5-Fluorouracil

Publish Year: 1396
نوع سند: مقاله ژورنالی
زبان: English
View: 340

This Paper With 6 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_TIPS-3-1_008

تاریخ نمایه سازی: 8 دی 1398

Abstract:

A reproducible, sensitive, accurate and selective high performance liquid chromatographic (HPLC) method with ultraviolet absorbance detection has been developed and validated to quantitate 5-Fluorouracil (5-FU), an antimetabolite chemotherapeutic agent used in treatment of colorectal cancer as a drug of choice. Chromatographic separations were performed on a C18 column (Eurosphar 100-5, 150 mm × 4.6 mm) as the reversed stationary phase, eluted with a mobile phase composed of deionized water and methanol (95:5) with the flow rate of 1.0 mL/min. The UV wavelength was set at 261nm. The method produced linear responses throughout 5-fluorouracil range of 25-500 ng/ml with a correlation coefficient of 0.998. A limit of quantitation (LOQ) was established at 25 ng/ml. The within-day and between-day precision and accuracy were both in acceptable ranges. The outcomes of these tests indicate a proper separation efficacy as well as accuracy and sensivity of method which is a potential tool in many pharmaceutical studies such as drug delivery of this anti-cancer agent.