The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Publish Year: 1398
نوع سند: مقاله ژورنالی
زبان: English
View: 317

This Paper With 10 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_IRJNM-27-2_001

تاریخ نمایه سازی: 19 بهمن 1398

Abstract:

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence of attenuation correction (AC) versus non-attenuation correction (NC) images and the effect of misregistration on all segments of SPECT images for quantitative and qualitative analysis. Methods: 99 patients (45 males, 54 females) underwent stress/rest myocardial perfusion imaging (MPI) using 99mTc-MIBI were used in this study. We also utilized cardiac insert and lung insert in cylinder phantom. Phantom studies were performed with and without defect. The misregistration of all patient data was measured and variation in misregistration of our population was recorded. The effect of attenuation correction (AC) and non-attenuation correction (NC) images were also evaluated in both phantom and patient data. The CT images were shifted by ±1, ±2, ±3 pixels along X-, Y- and Z-axis (Left/right, dorsal/ventral, cephalic/caudal) for both phantom and patient studies. Differences between misalignment data and misregistration correction images were also measured. Results displayed with 20 segments polar map analysis and illustration in standard orientations for cardiac tomographic images. Results:In the patient population data, 1.5% were perfectly registered, 17% and 73% misaligned under 1 pixel and more than 1 pixel, respectively. AC of SPECT images showed increased uptake value in normal phantom and false positives findings were disappeared versus to NC images. In patient data, statistically significant variation were shown for the most segments before and after AC (P-value<=0.004) and also between AC of SPECT image and misregistration correction images (P-value<=0.048). Along X-axis, in 3 pixel shift in right direction, the percent of relative difference in lateral wall were 11.94% for mid anterolateral. Along Y-axis, the Ventral shift caused -15.9% changes in basal inferolateral and along Z-axis -8.59 % changes in apical anterolateral were also observed in caudal direction when 3 pixel shifts were used. Conclusion: This study showed that CT-based attenuation correction of cardiac images in hybrid SPECT/CT is important to improve image quality. Misalignment in caudal, cephalad, ventral and right direction introduced significant variation even in 1 pixel shift. It is important to apply misregistration correction even in small misalignment routinely in clinical myocardial perfusion imaging.

Authors

Leila Saleki

Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran|Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran

Pardis Ghafarian

Chronic Respiratory Dis eases Research Center, National Research Institute of Tuberculosis and Lung Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran |PET/CT and Cyclotron Center of Masih Daneshvari Hospital, Shahid Beheshti

Ahmad Bitarafan-Rajabi

Cardiovascular Interventional Research Center, Department of Nuclear Medicine, Rajaei Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, Iran|Department of Nuclear Medicine, Rajaei Cardiovascular, Medical,

Nahid Yaghoobi

Cardiovascular Interventional Research Center, Department of Nuclear Medicine, Rajaei Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, Iran|Department of Nuclear Medicine, Rajaei Cardiovascular, Medical,

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Hachamovitch R. Prognostic characterization of patients with mild coronary artery ...
  • Russell RR 3rd, Zaret BL. Nuclear cardiology: present and future. ...
  • Zaidi H, Hasegawa BH. Attenuation correction strategies in emission tomography.  ...
  • Bybel B, Brunken RC, DiFilippo FP, Neumann DR, Wu G, ...
  • Goetze S, Brown TL, Lavely WC, Zhang Z, Bengel FM. ...
  • Geramifar P, Zafarghandi MS, Ghafarian P, Rahmim A, Ay MR. ...
  • Ay M, Shahriari M, Sarkar S, Ghafarian P. Measurement of ...
  • Ay MR, Mehranian A, Maleki A, Ghadiri H, Ghafarian P, ...
  • Ghafarian P, Aghamiri SM, Ay MR, Fallahi B, Rahmim A, ...
  • Ay MR, Mehranian A, Abdoli M, Ghafarian P, Zaidi H. ...
  • Etemadi Z, Ghafarian P, Bitarafan-Rajabi A, Malek H, Rahmim A, ...
  • Ghafarian P, Aghamiri SM, Ay MR, Rahmim A, Schindler TH, ...
  • Huang R, Li F, Zhao Z, Liu B, Ou X, ...
  • Gerdekoohi SK, Vosoughi N, Tanha K, Assadi M, Ghafarian P, ...
  • Goetze S, Wahl RL. Prevalence of misregistration between SPECT and ...
  • Ghafarian P, Ay M. The influence of PET and CT ...
  • Ghafarian P, Ay MR, Fard-Esfahani A, Rahmim A, Zaidi H. ...
  • Fricke E, Fricke H, Weise R, Kammeier A, Hagedorn R, ...
  • Heller GV, Bateman TM, Johnson LL, Cullom SJ, Case JA, ...
  • Patton JA, Turkington TG. SPECT/CT physical principles and attenuation correction. ...
  • Pazhenkottil AP, Ghadri JR, Nkoulou RN, Wolfrum M, Buechel RR, ...
  • Apostolopoulos DJ, Gąsowska M, Savvopoulos CA, Skouras T, Spyridonidis T, ...
  • Huang JY, Yen RF, Lee WC, Huang CK, Hsu PY, ...
  • Polycarpou I, Chrysanthou-Baustert I, Demetriadou O, Parpottas Y, Panagidis C, ...
  • Patchett ND, Pawar S, Miller EJ. Visual identification of coronary ...
  • Kennedy JA, Israel O, Frenkel A. Directions and magnitudes of ...
  • نمایش کامل مراجع