Cellular dosimetry of beta emitting radionuclides-antibody conjugates for radioimmunotherapy
Publish place: Iranian Journal of Nuclear Medicine، Vol: 27، Issue: 2
Publish Year: 1398
نوع سند: مقاله ژورنالی
زبان: English
View: 367
This Paper With 9 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IRJNM-27-2_010
تاریخ نمایه سازی: 19 بهمن 1398
Abstract:
Introduction: The choice of optimal radionuclides for radioimmunotherapy depends on several factors, especially the radionuclide and antibody. The dosimetric characteristics of a non-internalizing and an internalizing monoclonal antibody (MAb) labeled with beta emitting radionuclides were investigated. Methods: Using Geant4-DNA Monte Carlo simulation, we carry out dosimetric calculations for different subcellular distributions of beta-emitting radionuclides; 131I, 177Lu, 64Cu, 186Re and 153Sm. Results:The dependency of theradialdose profiles on the energy spectra of electrons (beta particles and Auger and internal conversion electrons) and also their relative yield of emission is clear. The highest difference between the radionuclides tested was observed when the activity was localized in the nucleus. There was not considerable difference in the nucleus dose when radionuclides were localized in cytoplasm and over the cell membrane. Conclusion: There is a very significant increase in the dose deposited to the nucleus if 153Sm localized at the nucleus. Although subcellular localization of activity isn’t a critical factor for beta emitting radionuclides, but the use of internalizing MAbs leads to an increase in nucleus dose and to the killing of single cells in addition to the tumors.
Keywords:
Authors
Parisa Taheri
Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
Hossein Rajabi
Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
Fariba Johari Daha
Department of Radioisotope, Nuclear Science and Technology Research Institute, Tehran, Iran
Kamal Yavari
Radiopharmaceutical Research and Development Laboratory, Nuclear Science and Technology Research Institute, Tehran, Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :