CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Rapid Detection of Listeria monocytogenes Strains Isolated from Clinical and Non-Clinical Samples by Loop-Mediated Isothermal Amplification Method (LAMP)

عنوان مقاله: Rapid Detection of Listeria monocytogenes Strains Isolated from Clinical and Non-Clinical Samples by Loop-Mediated Isothermal Amplification Method (LAMP)
شناسه ملی مقاله: JR_IEM-4-3_002
منتشر شده در شماره ۳ دوره ۴ فصل در سال 1397
مشخصات نویسندگان مقاله:

n Aleyasin - Microbiology Department, Medicine Faculty, Iran University of Medical Science, Tehran, Iran
s Karimaei - Pathobiology Department, Public Health Faculty, Tehran University of Medical Sciences, Tehran, Iran
m Talebi - Microbiology Department, Medicine Faculty, Iran University of Medical Science, Tehran, Iran
m Kashanian - Obstetrics & Gynecology Department, Medicine Faculty, Iran University of Medical Science, Tehran, Iran
gh.r Irajian - Microbiology Department, Medicine Faculty, Iran University of Medical Science, Tehran, Iran

خلاصه مقاله:
Aims Diagnosis of Listeria monocytogenes infections is critical for epidemiological study and prevention of diseases. This study aimed at identifying Listeria monocytogenes isolates, using Loop-Mediated Isothermal Amplification Method (LAMP). Materials & Methods Listeria strains were obtained from clinical and seafood specimen. All Listeria strains were identified by standard microbiological and biochemical tests. The LAMP assay was performed at 65°C with a detection limit of 2.5 ng/μl for 46 min. Specific primers for the hylA gene were used to identify L. monocytogenes. The specificity of the assay was assessed, using DNA from L. monocytogenes ATCC 7644 and L. ivanovii ATCC 19119 and non-Listeria strains. Sensitivity of the LAMP assay was compared with polymerase chain reaction (PCR) method. Amplification LAMP products were visualized via calcein and manganous ions as well as agarose gel electrophoresis. Findings A total of 191 samples were obtained, including clinical and food samples. Then, 21 (10.9%) isolates were recovered from specimens. The LAMP results showed high sensitivity (97.2%) and specificity (100 %). The LAMP assay was higher sensitive than of the PCRassay.Conclusion This data showed that this method could be used as a sensitive, rapid, and simple identification tool for diagnosis of L. monocytogenes isolates and it may be suitable for epidemiological study plans

کلمات کلیدی:
Identification; Listeria monocytogenes; Epidemiological Study; Polymerase Chain Reaction

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/992036/