Role of FDG-PET/CT in Assessing the Correlation Between Blood Pressure and Myocardial Metabolic Uptake
Publish Year: 1399
نوع سند: مقاله ژورنالی
زبان: English
View: 248
This Paper With 10 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
این Paper در بخشهای موضوعی زیر دسته بندی شده است:
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JNMB-8-1_005
تاریخ نمایه سازی: 24 تیر 1399
Abstract:
Objective(s): We aimed to assess the association between blood pressure and LV myocardial uptake of FDG, hypothesizing that subjects with raised blood pressure would have higher FDG uptake.
Methods: We analyzed 86 healthy controls who underwent PET/CT imaging 180 minutes following FDG (4 MBq/Kg) administration. LV myocardial analysis was performed on axial sections using standard operator guided computer software (OsiriX MD). The average LV myocardial SUVmean (MSUVmean) was calculated for each subject. Subjects were assessed according to the 2017 ACC/AHA guidelines for high blood pressure in adults. Mean arterial blood pressure (MABP) was calculated for each patient. Regression models were employed for statistical analysis.
Results: The association of MSUVmean was more pronounced with DP (r=0.32, p=0.003) than SP (r=0.28, p=0.010); MABP was comparable (r=0.33, p=0.002). Correlations of MSUVmean with categorized BPs were: normal SP (r=0.27, p=0.010), elevated SP (r=0.28, p=0.009), stage 1 SP (r=0.27, p=0.010), stage 2 SP (r=0.28, p=0.008); normal DP (r=0.33, p=0.001), stage 1 DP (r=0.34, p=0.001), stage 2 DP (r=0.35, p=0.001). Multivariate analysis demonstrated DP (p=0.006), MABP (p=0.007), and SP (0.026).
Conclusion: LV myocardial FDG uptake was higher in subjects with elevated blood pressure and correlated positively with SBP and in particular DBP and MABP.
Keywords:
Authors
Chaitanya Rojulpote
Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, United States
Siavash Seraj
Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, United States
Mahdi Zadeh
Department of Radiology, Children’s Hospital of Philadelphia, Philadelphia, United States
Divya Yadav
Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, United States
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :