Influence of wall mounted baffle on suppressing sloshing in a rectangular tank

Publish Year: 1400
نوع سند: مقاله کنفرانسی
زبان: English
View: 240

This Paper With 14 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

CAUICNF06_007

تاریخ نمایه سازی: 12 دی 1400

Abstract:

In this paper, a numerical model was developed to simulate the sloshing phenomenon in a rectangular tank with a wall mounted baffle. The influence of different parameters including the water filling level, the baffle location, and the baffle length were evaluated on the suppressing sloshing in a rectangular tank. Finally, some suggestions were presented to optimize the efficiency of the baffles. Finally, the wall mounted baffles located at Hb/Ht=۰.۳۵m and Lb/Lt=۰.۲-۰.۲۵ was suggested as the optimum one in which the swash force arises from the sloshing impact was mitigated around ۷۵%.

Authors

Reza Saghi

Msc of Hydraulic engineering, Department of Civil Engineering, Islamic Azad University, Mashhad branch, Mashhad, Iran

Hassan Saghi

Associate professor, Department of Civil Engineering, Hakim Sabzevari University, Sabzevar, Iran