Experimental Study of a Two-Phase Thermosyphon Loop in Conditions of High Fluidic and Thermal Loads

Publish Year: 1398
نوع سند: مقاله ژورنالی
زبان: English
View: 132

This Paper With 7 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_JAFM-12-0_008

تاریخ نمایه سازی: 15 دی 1400

Abstract:

An experimental study was conducted on a two-phase thermosyphon loop with a total length of ۲.۱ m, using Ethanol as a working fluid. The influence of the filling ratio, at ۴۰ and ۶۲%, on the thermo-hydraulic behavior was investigated. The applied heat fluxes on the evaporator are ranged between ۱۰ and ۶۰ W/cm۲, which corresponds to high values compared to those published elsewhere. One can notice that the confinement conditions associated with high filling ratios contribute to the training of the liquid phase from the evaporator to the condenser, which increases the drying limit of the evaporator due to a significant increase of the flow rate of the sub-cooled liquid at the inlet of the evaporator.

Authors

S. Adjmi

Chadli Bendjedid Univ, LPM, El Tarf, ۳۶۰۰۰, Algérie

S. Launay

Aix Marseille Univ, CNRS, IUSTI, Marseille, ۱۳۴۵۳, France

C. Abid