Comparison of IVP-simulator and ۹۹mTc-DMSA renal scaning for renal localization and shielding in candidates for radiation therapy [Persian]

Publish Year: 1379
نوع سند: مقاله ژورنالی
زبان: English
View: 158

This Paper With 6 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_IRJNM-8-1_006

تاریخ نمایه سازی: 7 تیر 1401

Abstract:

To minimize renal radiation in abdomical radiotherapy, shielding of the kidneys is essential. IVP-simulator is used as an standard method. In this study, we used ۹۹mTc-DMSA to localize and shield the Kidneys and we compared this method with IVP-simulator. The size of the kidneys was proven to be larger as compared with IVP method. The mean of the overlap percentage was ۸۱.۸۸ in right and ۸۲.۸۹ in left kidney. The confidence interval between two methods ranged from ۲۰ to ۸۰ percent. It is concluded that this is a useful method and can be recommended for localization and shielding of the kidneys in patients with abdominal radiotherapy.

Authors

Seyed Hossein Mortazavi

Imam Hossein Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Mojtaba Ansari

Imam Hossein Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Reza Khodabakhshi

Imam Hossein Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran