High Impedance Fault Detection in Power Transmission Lines Using Hilbert Transform and Instantaneous Frequency

Publish Year: 1402
نوع سند: مقاله ژورنالی
زبان: English
View: 196

This Paper With 12 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_IECO-6-1_001

تاریخ نمایه سازی: 10 اردیبهشت 1402

Abstract:

Power transmission lines are vital components of today's power systems. These power lines transmit the electricity produced in power plants in high volume and with very low losses to distant areas so that it can be reached to consumer through distribution networks. In fact, these lines are the intermediary between major energy producers and distribution networks. Accordingly, these transmission lines are of a great importance and must be protected appropriately with a suitable protection system. Distance relays are widely used to protect these lines due to their convenient coordination characteristics and simplicity. High impedance fault (HIF) can be a critical challenge for distance relays due to their low current amplitude and similarity to conventional events in power systems such as capacitive bank switching. For this reason, in this paper a new approach is presented based on the instantaneous frequency variations obtained from the current RMS in order to detect the high impedance fault. This method detects high impedance faults via calculating a Detection index (DI) and considering a threshold value. The proposed method has been tested using DIgSILENT and MATLAB software in an IEEE standard ۳۹-bus network. The presented results evidently demonstrate that the proposed method is suitable for detecting HIF and Low impedance fault (LIF). In addition, this method has a proper performance during capacitor bank switching and can well distinguish between HIF and capacitive bank switching. Moreover, the presented method is resistant to noise and also is capable to detect the faulty phase.

Authors

Hassan Abniki

Deputy Director General of the Office of Research and Technology Development, Tavanir Co., Tehran, Iran

Mostafa Hajati Samsi

Qazvin Islamic Azad University, Qazvin, Iran.

Behrooz Taheri

Young Researchers and Elite Club, Qazvin Branch, Islamic Azad University, Qazvin, Iran.

Seyed Amir Hosseini

Isfahan University of Technology

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • J. Doria-Garcia, C. Orozco-Henao, L. Iurinic, and J. D. Pulgarín-Rivera, ...
  • J. Doria-García, C. Orozco-Henao, R. Leborgne, O. D. Montoya, and ...
  • B. Taheri, S. A. Hosseini, H. Askarian-Abyaneh, and F. Razavi, ...
  • S. Vlahinić, D. Franković, B. Juriša, and Z. Zbunjak, "Back ...
  • B. Taheri and S. A. Hosseini, "Detection of High Impedance ...
  • B. Taheri, S. A. Hosseini, S. Salehimehr, and F. Razavi, ...
  • T. Lai, L. Snider, E. Lo, and D. Sutanto, "High-impedance ...
  • S. Nezamzadeh‐Ejieh and I. Sadeghkhani, "HIF detection in distribution networks based ...
  • R. Bhandia, J. de Jesus Chavez, M. Cvetković, and P. ...
  • W. Santos, F. Lopes, N. Brito, and B. Souza, "High-impedance ...
  • M. S. Tonelli-Neto, J. G. M. Decanini, A. D. P. ...
  • I. Baqui, I. Zamora, J. Mazón, and G. Buigues, "High ...
  • X. Wang et al., "High impedance fault detection method based ...
  • M. Faghihlou, B. Taheri, and S. Salehimehr, "High Impedance Fault ...
  • E. Sortomme, S. Venkata, and J. Mitra, "Microgrid protection using ...
  • N. Faridnia, H. Samet, and B. D. Dezfuli, "A new ...
  • M. Kavi, Y. Mishra, and M. D. Vilathgamuwa, "High-impedance fault ...
  • S. Gautam and S. M. Brahma, "Detection of high impedance ...
  • H. Livani and C. Y. Evrenosoglu, "A machine learning and ...
  • M. M. Ghalesefidi and N. Ghaffarzadeh, "A new phaselet-based method ...
  • S. Salehimehr, B. Taheri, F. Razavi, M. Parpaei, and M. ...
  • B. Taheri and M. Sedighizadeh, "Detection of power swing and ...
  • R. F. Espinoza, O. Dias, M. C. Tavares, and Y. ...
  • S. Roy and S. Debnath, "PSD based high impedance fault ...
  • M. Paul and S. Debnath, "Wavelet based single Ended scheme ...
  • V. Ashok and A. Yadav, "Fault diagnosis scheme for cross-country ...
  • B. Taheri, S. Salehimehr, F. Razavi, and M. Parpaei, "Detection ...
  • H. Teimourzadeh, A. Moradzadeh, M. Shoaran, B. Mohammadi-Ivatloo, and R. ...
  • C. Rahmann and A. Castillo, "Fast frequency response capability of ...
  • A. Korpel, "Gabor: frequency, time, and memory," Applied optics, vol. ...
  • S. Salehimehr, B. Taheri, S. A. Hosseini, H. Askarian Abyaneh, ...
  • S. L. Hahn, Hilbert transforms in signal processing. Artech House ...
  • M. Feldman, "Hilbert transform in vibration analysis," Mechanical systems and ...
  • S. Salehimehr, B. Taheri, and M. Faghihlou, "Detection of power ...
  • N. Kagan et al., "Influence of rms variation measurement protocols ...
  • Taheri, Behrooz, and Mostafa Sedighizadeh. "A moving window average method ...
  • R. B. Grimaldi, T. S. Chagas, J. Montalvao, N. S. ...
  • J. C. García, V. V. García, and N. Kagan, "Detection ...
  • S. A. Hosseini, B. Taheri, H. A. Abyaneh, and F. ...
  • نمایش کامل مراجع