Early detection of epoxy coated St-۳۷ underlying corrosion by fluorescent indicator

Publish Year: 1394
نوع سند: مقاله ژورنالی
زبان: English
View: 69

This Paper With 12 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_ICAC-5-17_002

تاریخ نمایه سازی: 5 آذر 1402

Abstract:

In the present work, the application of ۸-hydroxyquinoline (۸-HQ) as a ferric ion sensitive indicator, in epoxypolyamine coating was investigated. Having turn-on mechanism and showing no prematurely fluorescence when mixed with the coating precursors make ۸HQ useful for detecting undercoating corrosion of St-۳۷ which is covered by epoxy coating. The effect of different concentrations of ۸HQ(۰.۰۵,۰.۱,۰.۵,۱w.t%) in epoxy coating, on corrosion detection, optical, electrochemical and adhesion properties of applied coating were studied respectively by fluorescence microscopy, UV- Visible spectroscopy, electrochemical impedance spectroscopy and Pull-off methods. In the process, the sample with ۰.۱w.t% of ۸HQ not only, showed acceptable corrosion detection performance, but also was good in optical, electrochemical and adhesion properties.