Optical Efficiency of Linear Fresnel Reflectors in Fixed, Variable and Optimal Distance between Mirrors: Theoretical and Experimental Studies

Publish Year: 1403
نوع سند: مقاله ژورنالی
زبان: English
View: 70

This Paper With 15 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_IJE-37-2_006

تاریخ نمایه سازی: 15 آذر 1402

Abstract:

In linear Fresnel reflectors, field arrangement has a significant effect on optical efficiency. Three constant, optimal, and variable distance layouts are proposed for Fresdemo solar power plant. The study was carried out by simulation and experiment. The small-scale Fresnel concentrator was designed and built with the capability to implement these three arrangements. The optical efficiency of the solar power plant with optimal variable and constant gap between mirrors were compared, considering fixed conditions for all layouts, including overall dimensions of the plant, width, and number of mirrors and dimensions of the receiver. It was observed that the arrangement with the optimal variable, and fixed distance had the highest to the lowest energy efficiency. Besides, the mirrors farther from the center entail more losses due to the sharper tilt angles, hence more spaces between these mirrors is required to reduce the losses. Meanwhile, the last mirrors in fixed distance arrangement have severe losses of shading and blocking while, they produce almost the same energy as central mirrors in the optimal and variable distance arrangement. The experimental results of the developed prototype showed that the thermal efficiency for the optimal distance was the highest, while it was followed closely by variable distance arrangement. The fixed distance arrangement had the lowest thermal efficiency. In addition, the variable and optimal distance arrangements exhibited an efficiency of ۵۴% and ۵۵%, respectively.

Authors

A. Nakhaei Zadeh

Department of Mechanical Engineering, Shahid Bahonar University of Kerman, Kerman, Iran

M. Ameri

Department of Mechanical Engineering, Shahid Bahonar University of Kerman, Kerman, Iran

A. Shojaei

Department of Mechanical Engineering, Shahid Bahonar University of Kerman, Kerman, Iran

I. Baniasad Askari

Department of Mechanical Engineering, University of Zabol, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Sadeghi S, Baniasad Askari I. Performance and economic investigation of ...
  • Zhang H, Baeyens J, Degrève J, Cacères G. Concentrated solar ...
  • Morin G, Dersch J, Platzer W, Eck M, Häberle A. ...
  • Kuchkarov A, Abdumuminov A, Abdurakhmanov A. Developing a Design of ...
  • Santos AV, Canavarro D, Collares-Pereira M. The gap angle as ...
  • نمایش کامل مراجع