Investigating the Sensitivity of New Formulation MAGAT and NIPAM Polymer Gels in the Radiation Therapy Dosimetry
Publish Year: 1401
نوع سند: مقاله ژورنالی
زبان: English
View: 107
This Paper With 8 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JBPE-12-5_006
تاریخ نمایه سازی: 30 دی 1402
Abstract:
Background: Normoxic polymer gels have been used as a three dimensional (۳D) dosimeter in radiation therapy, recently. The sensitivity of these gels is important in dosimetry and their improvement can be also useful.Objective: In this study, different modalities of gel reading were used and the structure of gel changed due to the best improvement of sensitivity. The sensitivities of the new formulation of Methacrylic acid gel (MAGAT) and N-isopropyl acrylamide (NIPAM) polymer gel dosimeters were studied using two different reading methods of magnetic resonance imaging (MRI) and X-ray computed tomography (X-ray CT).Material and Methods: In this experimental study, in addition to making the NIPAM polymer gel dosimeter, a new formulation of normoxic polymer gel dosimeter, which named MAGAT gel, was investigated. The gels were irradiated with ۶ MV in low doses, including۱, ۱.۵, ۱.۷۵, ۲ and ۲.۵ Gy. MRI and X-ray CT did the reading of gel dosimeters a day after irradiation using an elevated protocol.Results: The dose sensitivities of ۰.۹۲ HGy-۱ and ۰.۴۷ HGy-۱ were obtained for new MAGAT and NIPAM polymer gel dosimeters, respectively, based on the X-ray CT reading modality. The use of MRI reading modality and the dose sensitivities were ۰.۷۴ S-۱Gy-۱ and ۰.۲۷ S-۱Gy-۱ for new MAGAT and NIPAM polymer gel dosimeters, respectively.Conclusion: The new formulation of MAGAT polymer gel with a suitable protocol of gel reading has a better response.
Keywords:
Authors
- -
PhD Candidate, Department of Physics, Sanandaj Branch, Islamic Azad University, Sanandaj, Iran
- -
PhD, Department of Medical Physics, Faculty of Medicine, Kurdistan University of Medical Sciences, Sanandaj, Iran
- -
PhD, Department of Physics, Sanandaj Branch, Islamic Azad University, Sanandaj, Iran
- -
PhD, Department of Physics, Sanandaj Branch, Islamic Azad University, Sanandaj, Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :