Effects of Rewash on the Accuracy of Stone Dies Produced by Putty-Wash Technique
Publish Year: 1392
نوع سند: مقاله ژورنالی
زبان: Persian
View: 97
This Paper With 10 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JKMU-20-6_007
تاریخ نمایه سازی: 14 اسفند 1402
Abstract:
Background and Aims: An accurate impression of teeth and supporting structure is necessary to restore a lost tooth structure or to replace a tooth with crown and bridge. Although there are various methods for making impression, putty-wash technique is currently preferred since it is simple and does not require a special tray. Silicone elastomeric impression materials have suitable consistency for putty-wash technique and are thus widely used. Considering the existing controversies over the effects of impression technique on the accuracy of restoration, we evaluated the effects of rewash on the accuracy of stone dies produced by a putty-wash technique. Methods: In this laboratory study, a model with two metallic dies was used. One die had a horizontal notch as an undercut. Ten impressions were made with spacer and ten impressions with rewash technique. A profile meter with accuracy of one micron was used to measure the dimensions of the produced stone models. The original and produced models were compared by t-test. Results: The mean height of dies without undercut decreased significantly in both groups (۱۱.۶۹ with spacer, P < ۰.۰۰۱ and ۱۱.۴۴ with rewash P < ۰.۰۰۱). The mean diameter of dies without undercut decreased in both groups (۱۰.۳۹ with spacer and ۱۰.۲۷ with rewash) but the difference was only significant using rewash technique (P = ۰.۰۱۸). The mean distance between two dies increased in both techniques (۳۰.۲۵ with spacer and ۳۰.۴۳ with rewash). Again, the difference was only significant using rewash technique (P < ۰.۰۰۱). The mean diameter of dies below the undercut increased with spacer technique (۱۰.۳۳; P > ۰.۰۵) and decreased with rewash technique (۱۰.۲۱; P < ۰.۰۰۱). The mean height of dies above the undercut decreased significantly in both groups (۹.۹۹ with spacer P < ۰.۰۰۱ and ۱۰.۲۱ with rewash P < ۰.۰۰۱). Conclusion: The impression technique with spacer was more accurate in all dimensions as compared to rewash technique.
Keywords:
Impression technique , Dimensional accuracy of impression , Impression materials , Condensation , Silicone
Authors
P Amini
Associate Professor, Department of Prosthodontics School of Dentistry, Kerman University of Medical Sciences, Kerman, Iran
M Tavalaei
Resident, Department of Community Dentistry, School of Dentistry, Kerman University of Medical Sciences, Kerman, Iran