Agreement between methods of retinoscopy, conventional subjective refraction and fogging subjective refraction

Publish Year: 1403
نوع سند: مقاله ژورنالی
زبان: English
View: 69

This Paper With 5 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_RCM-11-1_003

تاریخ نمایه سازی: 10 مرداد 1403

Abstract:

Purpose: to compare the refractive error measurements achieved through three distinct techniques: retinoscopy, subjective method, and the subjective fogging method. Methods: Participants included ۲۲۳ young adults aged ۱۸ to ۳۶ years (mean age: ۲۵.۶۳±۵.۳۱). The refractive error of one eye was measured under three different accommodation control conditions: subjective refraction, fogging subjective refraction and retinoscopy.Results: Data were collected for ۲۲۳ young adults. The average Spherical value obtained by the retinoscopy method was ۰.۲۱ and the average cylinder was -۰.۷۶. These values were -۰.۰۱ and -۰.۷۵, respectively, in the subjective with fog method: The Spherical value and cylinder obtained by the regular subjective method were -۰.۱۳ and -۰.۷۴ D, respectively; The mean spherical equivalent with subjective refraction method was more minus than fogging subjective refraction and retinoscopy provided the most plus results. the difference in spherical and spherical equivalent value between three methods was significant (p- value< ۰.۰۰۱) but the difference in cylindrical value between three groups was not significant (p- value> ۰.۰۵). According to the Intraclass Correlation Coefficient analysis, the agreement between three methods for measuring sphere (ICC= ۰.۹۹), cylinder (ICC= ۰.۹۵) and spherical equivalent (ICC= ۰.۹۹) was good.Conclusions: The results showed that retinoscopy and fogging subjective refraction were the most similar methods, with a small mean difference. However, the comparison between retinoscopy and subjective refraction had wider limits of agreement than retinoscopy and fogging subjective refraction. Key words: Retinoscopy, subjective, refraction, fogging

Authors

Atefeh Kebriaei

Department of optometry, School of rehabilitation sciences, Shahid beheshti university of medical sciences, Tehran, Iran.

Asieh Ehsaei

۱. Department of Optometry, School of paramedical sciences, Mashhad University of Medical Sciences, Mashhad, Iran. ۲. Refractive errors research center, Mashhad university of medical sciences, Mashhad, Iran.

Hadi Ostadimoghaddam

۱. Refractive Errors Research Center, Mashhad University of Medical Sciences, Mashhad, Iran ۲. Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran

Elham Bakhtiari

Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

Mojtaba Salamati

Department of optometry, School of paramedical sciences, Mashhad university of medical sciences, Mashhad, Iran.

NEGAREH YAZDANI

۱. Department of optometry, School of paramedical sciences, Mashhad University of Medical Sciences, Mashhad, Iran. ۲. Refractive errors research center, Mashhad university of medical sciences, Mashhad, Iran.

Shima Mesbahi

Department of optometry, School of paramedical sciences, Mashhad university of medical sciences, Mashhad, Iran.