Comparison of Saturated Parameters of Three-Layer Interior Permanent Magnet Synchronous Machine Obtained from Lumped Parameter Model and Finite Element Method
Publish place: 21th Iranian Conference on Electric Engineering
Publish Year: 1392
نوع سند: مقاله کنفرانسی
زبان: English
View: 1,082
This Paper With 5 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
ICEE21_472
تاریخ نمایه سازی: 27 مرداد 1392
Abstract:
In this paper, the Lumped-Parameters Model is used for calculation of Q and D-axis inductances of three-layer Interior Permanent Magnet machine. The model includesconsidering all details of flux barrier and air bridges of rotor and also the effect of saturation in central posts and stator core.Q and D-axis inductances are used for calculation of the average torque. To validate the model, results are compared with the Finite Element Analysis results for a candidate IPMS machine.
Keywords:
Authors
H. Mirahki
Isfahan University of Technology