Abstract:

Introduction: Since the Ordered Subset Expectation Maximization (OSEM) and Q.Clear algorithm each have advantages and disadvantages, we aimed to determine the optimal values of reconstruction protocols to achieve the best diagnostic parameters for the neurological PET brain images of  BGO-based PET/CT scanners. Methods: Images of point sources, as well as Hoffman and Carlson phantoms filled with [۱۸F]FDG radiopharmaceutical, were acquired using a PET/CT scanner. In OSEM, images were reconstructed with multiple iterations and subsets, applying ۳.۲ mm or ۶.۴ mm Gaussian filters, with PSF recovery enabled. For comparison, one reconstruction was done without PSF recovery using Iteration-Subset=۱۲–۱۲. In Q.Clear, β values from ۵۰ to ۵۰۰ in ۵۰-step increments were used for reconstruction. Parameters such as FWHM, COV and modified RC were evaluated. A cost function identified the best results, which were blindly assessed by two nuclear medicine experts for noise, contrast, and overall image quality.Results: Quantitatively, β=۵۰-۲۰۰ and Iteration-Subset=۲۰-۱۲ were the parameters whose Cost Function values were higher than Iteration-Subset =۱۲-۱۲, which was routinely used to reconstruct brain images in our center. Visual evaluations show that β=۲۰۰ has the lowest noise and the lowest contrast and evaluators gave the highest score for overall image quality to β=۲۰۰ and β=۱۵۰. This study has evaluated β=۲۰۰ and β=۱۵۰ as optimal for reconstructing brain images.Conclusions: This study investigated the different reconstruction algorithms to obtain the optimal parameters. The Q.clear algorithm with penalty function of β=۲۰۰ and β=۱۵۰ is recommended for brain neurological images of GE Healthcare PET/CT scanner.

Authors

Mahsa Asami

Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran

Farahnaz Aghahosseini

Department of Nuclear Medicine, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran

Saeed Farzanehfar

Department of Nuclear Medicine, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran

Pardis Ghafarian

PET/CT and Cyclotron Center, Masih Daneshvari Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Yalda Salehi

Department of Nuclear Medicine, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran

Mohammadreza Ay

Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran

Nima Kasraie

Department of Radiology, UT Southwestern Medical Center, Dallas, TX ۷۵۳۹۰-۹۰۷۱, USA

Peyman Sheikhzadeh

Research Center for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Ikari Y, Akamatsu G, Nishio T, Ishii K, Ito K, ...
  • Akamatsu G, Ikari Y, Nishio T, Nishida H, Ohnishi A, ...
  • Yoshii T, Miwa K, Yamaguchi M, Shimada K, Wagatsuma K, ...
  • Akamatsu G, Ishikawa K, Mitsumoto K, Taniguchi T, Ohya N, ...
  • Ross S. Clear white paper. Chicago, IL: GE Healthcare. ۲۰۱۴. ...
  • Miwa K, Yoshii T, Wagatsuma K, Nezu S, Kamitaka Y, ...
  • Miwa K, Wagatsuma K, Nemoto R, Masubuchi M, Kamitaka Y, ...
  • Reynés-Llompart G, Gámez-Cenzano C, Romero-Zayas I, Rodríguez-Bel L, Vercher-Conejero JL, ...
  • Al-Fatlawi M, Pak F, Farzanefar S, Salehi Y, Monsef A, ...
  • Sadremomtaz A, Taherparvar P. The influence of filters on the ...
  • Jonmarker O, Axelsson R, Nilsson T, Gabrielson S. Comparison of ...
  • Sadeghi F, Sheikhzadeh P, Farzanehfar S, Ghafarian P, Moafpurian Y, ...
  • Lindström E, Oddstig J, Danfors T, Jögi J, Hansson O, ...
  • نمایش کامل مراجع