Improving allergy testing and diagnosis: impact of skin prick testing intra-head device variability on clinical performance
Publish Year: 1402
نوع سند: مقاله ژورنالی
زبان: English
View: 86
This Paper With 7 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJPM-2-2_001
تاریخ نمایه سازی: 30 مهر 1404
Abstract:
Background: Multiple head skin prick test (SPT) devices designed for percutaneous allergy testing suffer from intra-head device variability, which may lead to misinterpretations by testing physicians impacting allergy treatment. It is proposed that detailed, high-magnification inspection during the verification stage of the design and development process of SPT devices would improve clinical accuracy and performance. Objectives: This pilot study aimed to examine the impact of physical characteristics, including consistency of length and the precision of the tips of the applicator tines of two FDA commercially available SPT devices, on clinical performance. It was hypothesized that devices with lower finished product variability would improve clinical performance.Methods: Visual inspection the Lincoln Multi-Test II (LM) and the ST-۹® multiple head applicator (ST-۹) were obtained by dimensional measurement using ۱۶۰X magnification. A total of ۸ subjects completed this pilot study. SPT with histamine (HIS; ۱ mg/mL base) and saline glycerin (GLY) were applied on the volar surface of one forearm LM and ST-۹ devices using on the opposite forearm. Data were obtained from ۷۲ histamine sites for the ST-۹ device and ۶۴ histamine sites for the LM device with ۷۲ negative control GLY sites recorded for the ST-۹ device and ۶۴ glycerinated GLY sites for the LM device.Results: T-test revealed that the ST-۹® employed a statistically significant shorter tine length (۱.۹۴ ± ۰.۰۲) and showed less variability of tine length (P < ۰.۰۵) compared with the LM (۲.۱۲ ± ۰.۰۳). The ST-۹ showed a smaller tip diameter and significantly less tine point diameter variability (۰.۰۳۷ ± ۰.۰۰۶) (P < ۰.۰۵) compared to LM (۰.۰۴۲ ± ۰.۰۰۹). The ST-۹™ displayed significantly (P<۰.۰۵) less wheal reaction to the negative control glycerin GLY solution than LM.Conclusion: The lower variability of ST-۹® suggests less likely operator misinterpretations. Although considered an engineering design and manufacturing problem, precision and high magnification inspection during the verification stage of SPT devices may have important clinical implications. Studies on optimizing the magnification process to improve the precision and performance of SPT devices in the clinical setting are warranted.
Keywords:
Authors
Marcos Sanchez-Gonzalez
Lake Erie College of Osteopathic Medicine, Bradenton, FL, USA
Troy Grogan
MedScience Research Group, West Palm Beach, FL, USA
Marvin Smollar
MedScience Research Group, West Palm Beach, FL, USA
Syed Rizvi
College of Biomedical Sciences, Larkin University, Miami, FL, USA
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :