A simple non-invasive I-123-IMP autoradiography method developed by modifying the simple non-invasive I-123-IMP microsphere method
Publish Year: 1397
نوع سند: مقاله ژورنالی
زبان: English
View: 297
This Paper With 7 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JNMB-6-1_007
تاریخ نمایه سازی: 12 تیر 1398
Abstract:
Objective: We developed a simple non-invasive I-123-N-isopropyl-p-iodoamphetamine (123I-IMP) quantification method by analyzing chest RI-angiography and single photon emission computed tomography (SPECT) images based on the microsphere model (SIMS method). Theoretically, the SIMS method could be changed to the simple non-invasive ARG (SIARG) method by modifying the integrated washout ratio (WR) to one-point WR. If the regional cerebral blood flow (rCBF) values derived from the SIARG and ARG methods correlate well, the facilities employing the ARG method can easily switch to the SIARG method. The purpose of this study was to develop the SIARG method by modifying the SIMS method and to confirm the feasibility of this method. Methods: The correlation between the input counts of the SIARG method and the blood counts was determined by linear regression analysis. The rCBF values determined by the SIARG method were compared with the values obtained with the ARG and SIMS methods. Results: There was a good linear correlation between the SIARG counts and the arterial blood counts obtained by the ARG method (r = 0.85, p < 0.001, n = 29). TherCBF values obtained by the ARG and SIARG methods (n = 29, 696 ROIs) correlated well (y = 1.01x – 3.6, r = 0.85, p < 0.001). Similarly, the rCBF values obtained by the SIARG and SIMS methods (n = 29, 696 ROIs) correlated well (y = 0.98x – 15.2, r = 0.90, p < 0.001). rCBF values obtained by the SIARG method were almost the same as the values obtained by the ARG method, and values of the SIMS method were 15 ml/100g/min higher that of those obtained by the SIARG method. Conclusions: The rCBF values obtained by the ARG, SIARG, and SIMS methods correlated very well. Therefore, the SIARG method is potentially useful for examinations in routine clinical practice.
Keywords:
Authors
Asato Ofuji
Graduate School of Health Sciences, Kumamoto University, Kumamoto , Japan
Rieko Nagaoka
Department of Radiology, Clinical Research Institute, National Hospital Organization Kyushu Medical Center, Jigyouhama ۱-۸-۱, Chuo-ku, Fukoka ۸۱۰-۸۵۶۳, Japan
Kosuke Yamashita
Fujifilm RI Pharma Co.,Ltd. ۱۴-۱Kyobashi, ۲-choume, chuo-ku, Tokyo, ۱۰۴-۰۰۳۱, Japan
Akihiro Takaki
Faculty of Life Sciences, Kumamoto University, Kuhonji ۴-۲۴-۱, Chuo-ku, Kumamoto ۸۶۲-۰۷۹۶, Japan
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :