سیویلیکا را در شبکه های اجتماعی دنبال نمایید.

Seismic Retrofit of Rectangular Concrete Columns with Splice Deficiencies by External Prestressing

Publish Year: 1382
Type: Conference paper
Language: English
View: 2,166

This Paper With 8 Page And PDF Format Ready To Download

Export:

Link to this Paper:

Document National Code:

SEE04_SS15

Index date: 1 November 2005

Seismic Retrofit of Rectangular Concrete Columns with Splice Deficiencies by External Prestressing abstract

Experimental research has been conducted to investigate the effectiveness of external prestressing as a seismic retrofit methodology for reinforced concrete bridge columns. The retrofit technique involves external prestressing concrete columns in transverse direction to improve their seismic performance.Rectangular columns with spliced longitudinal reinforcement have been tested with and without seismic retrofitting. It was observed that external prestressing improved bond between concrete and reinforcement in the splice region and resulted in improvements in inelastic column deformability. The paper outlines the experimental program employed and the test results obtained.

Seismic Retrofit of Rectangular Concrete Columns with Splice Deficiencies by External Prestressing authors

Majid Sadoughi Yarandi

Doctoral Candidate, Department of Civil Engineering, University of Ottawa, Ottawa, Canada

Murat Saatcioglu

Professor, Department of Civil Engineering, University of Ottawa, Ottawa, Canada,