Calculation of Separation Distance between Adjacent Buildings: A Review on Codal Provisions
Publish Year: 1394
Type: Journal paper
Language: English
View: 340
This Paper With 12 Page And PDF Format Ready To Download
- Certificate
- I'm the author of the paper
Export:
Document National Code:
JR_JSEE-17-1_002
Index date: 30 October 2021
Calculation of Separation Distance between Adjacent Buildings: A Review on Codal Provisions abstract
Structures are being built very close to each other in metropolitan areas where the cost of land is very high. Due to the proximity of the structures, they often collide with each other when subjected to earthquakes. To mitigate the amount of damage from pounding, the most simplest and effective way is to provide minimum separation distance. Generally most of the existing buildings in seismically moderate regions are built without codal provisions. The main objective of the present study is to check the adequacy of provisions given in codes of various countries. For this purpose, four pairs of structures were selected. The gap between structures was estimated according to codes of different countries and the same were subjected to earthquake excitation. Some codal provisions failed to satisfy the safety requirements, whereas some were safe. Based on this study, recommendations were drawn.
Calculation of Separation Distance between Adjacent Buildings: A Review on Codal Provisions Keywords:
Calculation of Separation Distance between Adjacent Buildings: A Review on Codal Provisions authors
Chenna Rajaram
International Institute of Information Technology
Ramancharla Pradeep Kumar
International Institute of Information Technology