MAGIC-f Gel Dosimeter Reading: A Comparison between an In-House Optical CT and MRI Imaging
Publish place: Iranian Journal of Medical Physics، Vol: 18، Issue: 6
Publish Year: 1400
نوع سند: مقاله ژورنالی
زبان: English
View: 250
This Paper With 8 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-18-6_008
تاریخ نمایه سازی: 20 آذر 1400
Abstract:
Introduction: According to new developments in radiation therapy techniques, accurate dose verification in three dimensions has become more critical. Polymer gel dosimeters (PGDs) are valuable tools to be used for this purpose. Nowadays, various imaging modalities are employed to read out the gels. This study was aimed to investigate the measured dose distribution recorded in MAGIC-f PGD with optical computed tomography (OCT) by comparison with MRI. Material and Methods: We developed an in-house charge-coupled device (CCD) based cone-beam OCT scanner. A phantom of MAGIC-f PGD was used to measure a four-field box dose distribution. MRI and OCT scanners were performed for gel readouts. Both measurement results were compared by gamma index analysis with various acceptance criteria. The temporal stability of the gel was also evaluated with the OCT readout system. Results: The percentage of isodose lines from two measured datasets agreed well together. The pass rates were ۹۹.۰۲%, ۹۶.۸%, and ۸۹.۸% with ۵%/۵mm, ۴%/۴mm, and ۳%/۳mm criteria, respectively, at the phantom's central axial slice. Conclusion: The results indicate that the performance of this OCT system is almost the same with acceptable discrepancies to the MRI as accepted standard readout modality, and it can be used for three-dimensional dose verifications.
Keywords:
Authors
Zahra Mansouri
Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Ahmad Mostaar
Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Mahmoud Shiri
Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Mohsen Sadat Shahabi
Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :