Utilizing Modern Experimentation Method to Quantify Jet-Breaker Dimension Effects on Drop Manhole Pool Height

Publish Year: 1397
نوع سند: مقاله ژورنالی
زبان: Persian
View: 132

This Paper With 12 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_CEJ-4-12_015

تاریخ نمایه سازی: 28 آذر 1400

Abstract:

Drop manholes are commonly employed in sewer and drainage systems to reduce pipes slope. The operation of these structures is dominated by their flow regime. Poor hydraulic performance of them under Regime R۲ was improved with the jet-breaker, which intersects the inlet jet; yet its proper dimensions were needed to be precisely determined. In this paper, effects of jet-breaker length, width, sagitta, and angle on drop manhole pool free-surface height were experimentally studied under ۸۰% filling ratio of the inlet pipe. The modern statistical Design of Experiment (DoE) methodology and dimensional analysis were utilized to design the experiments in accordance with the ۲۴-۱IV fractional factorial design. Consequently, nine specific jet-breakers were built and examined at two different angles, and under various flow rates. The statistical analysis of the results shown that manhole pool height was significantly decreased when jet-breaker length, width, and sagitta were ۱, ۱.۴, and ۰.۷ times the inlet pipe diameter, respectively, and its angle was at ۷۰°. The use of DoE resulted in ۲۱% reduction in experimental runs, cost, and time, while it provided comprehensive data analysis and objective conclusion.Keywords: Drop

Authors

Seyedreza Hasheminejad

Department of Civil Engineering, Shahid Bahonar University of Kerman, Kerman, Iran

Mohammad-Javad Khanjani

Department of Civil Engineering, Shahid Bahonar University of Kerman, Kerman, Iran

Gholam-Abbas Barani

Department of Civil Engineering, Shahid Bahonar University of Kerman, Kerman, Iran