سیویلیکا را در شبکه های اجتماعی دنبال نمایید.

Passive Control with Blade-End Slots and Whole-Span Slot in a Large Camber Compressor Cascade

Publish Year: 1400
Type: Journal paper
Language: English
View: 191

This Paper With 12 Page And PDF Format Ready To Download

Export:

Link to this Paper:

Document National Code:

JR_JAFM-14-3_004

Index date: 5 January 2022

Passive Control with Blade-End Slots and Whole-Span Slot in a Large Camber Compressor Cascade abstract

Suitable slot structure of the compressor blade can generate high-momentum jet flow through pressure difference between the pressure and suction surface, it has been proved that the slot jet flow can reenergize the local low-momentum fluid to effectively suppress the flow separation on the suction surface. In order to explore a slotted method for better comprehensive suppressing effects on the boundary layer separation near blade midspan and the three-dimensional corner separation, a diffusion stator cascade with large camber angle is selected as the research object. Firstly, the Slotted_1 and Slotted_2 whole-span slotted schemes are set up, then the Slotted_3 scheme with whole-span slot and blade-end slots is proposed, finally the performance of original cascade and slotted cascades is computed under a wide range of incidence angles at the Mach number of 0.7. The results show that: in the full range of incidence angles, compared with the whole-span slotted cascades, the development of the endwall secondary flow on the suction surface of Slotted_3 cascade is effectively suppressed, the degree of the mutual interference between the secondary flow and the main flow is reduced. Besides, on the suction surface of Slotted_3 cascade, the boundary layer separation near blade midspan and the corner separation are basically eliminated. As a result, compared with those of original cascade, the total pressure losses of Slotted_3 cascade are reduced in the full range of incidence angles, and its operating range of incidence angles is broadened. Moreover, compared with the whole-span slotted schemes, Slotted_3 scheme has a better adaptability to wide range of incidence angles.

Passive Control with Blade-End Slots and Whole-Span Slot in a Large Camber Compressor Cascade Keywords:

Passive Control with Blade-End Slots and Whole-Span Slot in a Large Camber Compressor Cascade authors

H. Wang

School of Power and Energy, Northwestern Polytechnical University, Xi’an, Shaanxi, ۷۱۰۰۷۲, P. R. China

B. Liu

School of Power and Energy, Northwestern Polytechnical University, Xi’an, Shaanxi, ۷۱۰۰۷۲, P. R. China

B. Zhang

School of Power and Energy, Northwestern Polytechnical University, Xi’an, Shaanxi, ۷۱۰۰۷۲, P. R. China